A Randomised Trial Comparing Drug Coated Balloons and Conventional Balloons for the Treatment of Stent Graft Stenosis in Dialysis Vascular Access
European Journal of Vascular and Endovascular Surgery · 2023
DOI: 10.1016/j.ejvs.2023.05.028 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift European Journal of Vascular and Endovascular Surgery, 2023. Verfasst von Mu-Yang Hsieh und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biological Science and Technology, National Yang Ming Chiao Tung University, Hsinchu, Taiwan; Division of Cardiology, Department of Int…. Hauptthemen laut MEDLINE: Arteriovenous Shunt, Surgical, Angioplasty, Balloon. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: National Taiwan University Hospital Hsin-Chu Branch, National Science and Technology Council, National Taiwan University Hospital.
Abstract (Originalsprache)
OBJECTIVE: Previous studies on arteriovenous fistulas have demonstrated the potential benefit of drug coated balloons (DCBs) in maintaining the patency of dialysis access. However, stenoses involving stent grafts were excluded from these studies. Therefore, the aim was to evaluate the effectiveness of DCBs in treating stent graft stenosis. METHODS: This was a prospective, single blinded, randomised controlled study. From March 2017 to April 2021, 40 patients with dysfunctional vascular access owing to stent graft stenosis were randomised to treatment with a DCB or conventional balloon. Clinical follow up was scheduled at one, three, and six months, and angiographic follow up was performed six months after the intervention. The primary outcome was angiographic late luminal loss at six months, and secondary outcomes included target lesion and access circuit primary patency at six months. RESULTS: Thirty-six participants completed follow up angiography. The DCB group had a superior mean late luminal loss at six months compared with the control group (1.82 mm ± 1.83 mm vs. 3.63 mm ± 1.08 mm, respectively, p = .001). All 40 patients completed clinical follow up. The DCB group had a superior six month target lesion primary patency compared with the control group [hazard ratio (HR) 0.23, 95% confidence interval (CI) 0.07 - 0.71; p = .005). Additionally, the DCB group had a numerically higher six month access circuit primary patency rate than the control group, although the difference was not statistically significant (HR 0.54, 95% CI 0.26 - 1.11, p = .095). CONCLUSION: Conventional balloon angioplasty is not durable in stent graft stenosis treatment. Treatment with DCBs provides less angiographic late luminal loss and potentially superior primary patency of the target lesion than treatment with conventional balloons. [ClinicalTrials ID: NCT03360279.].
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biological Science and Technology, National Yang Ming Chiao Tung University, Hsinchu, Taiwan; Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital Hsin-Chu Branch, H…
- Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital Hsin-Chu Branch, Hsinchu, Taiwan.
- Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital Hsin-Chu Branch, Hsinchu, Taiwan; College of Medicine, National Taiwan University, Taipei, Taiwan.
- Department of Biological Science and Technology, National Yang Ming Chiao Tung University, Hsinchu, Taiwan; Taipei Medical University and Hospital, Taipei, Taiwan.
- Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital Hsin-Chu Branch, Hsinchu, Taiwan; College of Medicine, National Taiwan University, Taipei, Taiwan; Institute of Biomedical Eng…
Förderung
- National Taiwan University Hospital Hsin-Chu Branch
- National Science and Technology Council
- National Taiwan University Hospital
Zitieren
APA
Hsieh, M. Y., Lin, P. S., Liao, M. T., Lin, L., Chen, T. Y., Boon, J. C., Yang, T. F., & Wu, C. C. (2023). A Randomised Trial Comparing Drug Coated Balloons and Conventional Balloons for the Treatment of Stent Graft Stenosis in Dialysis Vascular Access. European Journal of Vascular and Endovascular Surgery. https://doi.org/10.1016/j.ejvs.2023.05.028
Vancouver
Hsieh MY, Lin PS, Liao MT, Lin L, Chen TY, Boon JC, et al. A Randomised Trial Comparing Drug Coated Balloons and Conventional Balloons for the Treatment of Stent Graft Stenosis in Dialysis Vascular Access. European Journal of Vascular and Endovascular Surgery. 2023. doi:10.1016/j.ejvs.2023.05.028
BibTeX
@article{Hsieh2023,
author = {Hsieh, Mu-Yang and Lin, Pei-Shan and Liao, Min-Tsun and Lin, Lin and Chen, Tsung-Yan and Boon, Jong-Chien and Yang, Ten-Fang and Wu, Chih-Cheng},
title = {A Randomised Trial Comparing Drug Coated Balloons and Conventional Balloons for the Treatment of Stent Graft Stenosis in Dialysis Vascular Access},
journal = {European Journal of Vascular and Endovascular Surgery},
year = {2023},
doi = {10.1016/j.ejvs.2023.05.028}
}
EUVIMED