Optimization of anastomotic technique and gastric conduit perfusion with hyperspectral imaging and machine learning in an experimental model for minimally invasive esophagectomy
European Journal of Surgical Oncology · 2025
DOI: 10.1016/j.ejso.2023.04.007 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Surgical Oncology, 2025. Verfasst von F Nickel und 21 weiteren Autor:innen. Beteiligte Einrichtung: Department of General, Visceral, and Transplantation Surgery, Heidelberg University Hospital, Heidelberg, Germany; HIDSS4Health - Helmholtz Informati…. Hauptthemen laut MEDLINE: Esophagectomy, Anastomosis, Surgical, Hyperspectral Imaging, Machine Learning. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
INTRODUCTION: Esophagectomy is the mainstay of esophageal cancer treatment, but anastomotic insufficiency related morbidity and mortality remain challenging for patient outcome. Therefore, the objective of this work was to optimize anastomotic technique and gastric conduit perfusion with hyperspectral imaging (HSI) for total minimally invasive esophagectomy (MIE) with linear stapled anastomosis. MATERIAL AND METHODS: A live porcine model (n = 58) for MIE was used with gastric conduit formation and simulation of linear stapled side-to-side esophagogastrostomy. Four main experimental groups differed in stapling length (3 vs. 6 cm) and simulation of anastomotic position on the conduit (cranial vs. caudal). Tissue oxygenation around the anastomotic simulation site was evaluated using HSI and was validated with histopathology. RESULTS: The tissue oxygenation (ΔStO2) after the anastomotic simulation remained constant only for the short stapler in caudal position (-0.4 ± 4.4%, n.s.) while it was impaired markedly in the other groups (short-cranial: -15.6 ± 11.5%, p = 0.0002; long-cranial: -20.4 ± 7.6%, p = 0.0126; long-caudal: -16.1 ± 9.4%, p < 0.0001). Tissue samples from avascular stomach as measured by HSI showed correspondent eosinophilic pre-necrotic changes in 35.7 ± 9.7% of the surface area. CONCLUSION: Tissue oxygenation at the site of anastomotic simulation of the gastric conduit during MIE is influenced by stapling technique. Optimal oxygenation was achieved with a short stapler (3 cm) and sufficient distance of the simulated anastomosis to the cranial end of the gastric conduit. HSI tissue deoxygenation corresponded to histopathologic necrotic tissue changes. The experimental model with HSI and ML allow for systematic optimization of gastric conduit perfusion and anastomotic technique while clinical translation will have to be proven.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of General, Visceral, and Transplantation Surgery, Heidelberg University Hospital, Heidelberg, Germany; HIDSS4Health - Helmholtz Information and Data Science School for Health, Heidelberg and Karlsruhe, Germa…
- Department of General, Visceral, and Transplantation Surgery, Heidelberg University Hospital, Heidelberg, Germany; School of Medicine, Heidelberg University, Heidelberg, Germany.
- Department of General, Visceral, and Transplantation Surgery, Heidelberg University Hospital, Heidelberg, Germany.
- HIDSS4Health - Helmholtz Information and Data Science School for Health, Heidelberg and Karlsruhe, Germany; Division of Computer Assisted Medical Interventions, German Cancer Research Center (DKFZ), Heidelberg, Germany;…
- Department of Urology, Medical Faculty of Mannheim at the University of Heidelberg, Mannheim, Germany.
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, USA.
Zitieren
APA
Nickel, F., Studier-Fischer, A., Özdemir, B., Odenthal, J., Müller, L. R., Knoedler, S., Kowalewski, K. F., Camplisson, I., Allers, M. M., Dietrich, M., Schmidt, K., Salg, G. A., Kenngott, H. G., Billeter, A. T., Gockel, I., Sagiv, C., Hadar, O. E., Gildenblat, J., Ayala, L., …, & Müller-Stich, B. P. (2025). Optimization of anastomotic technique and gastric conduit perfusion with hyperspectral imaging and machine learning in an experimental model for minimally invasive esophagectomy. European Journal of Surgical Oncology. https://doi.org/10.1016/j.ejso.2023.04.007
Vancouver
Nickel F, Studier-Fischer A, Özdemir B, Odenthal J, Müller LR, Knoedler S, et al. Optimization of anastomotic technique and gastric conduit perfusion with hyperspectral imaging and machine learning in an experimental model for minimally invasive esophagectomy. European Journal of Surgical Oncology. 2025. doi:10.1016/j.ejso.2023.04.007
BibTeX
@article{Nickel2025,
author = {Nickel, F and Studier-Fischer, A and Özdemir, B and Odenthal, J and Müller, L R and Knoedler, S and Kowalewski, K F and Camplisson, I and Allers, M M and Dietrich, M and Schmidt, K and Salg, G A and Kenngott, H G and Billeter, A T and Gockel, I and Sagiv, C and Hadar, O E and Gildenblat, J and Ayala, L and Seidlitz, S and Maier-Hein, L and Müller-Stich, B P},
title = {Optimization of anastomotic technique and gastric conduit perfusion with hyperspectral imaging and machine learning in an experimental model for minimally invasive esophagectomy},
journal = {European Journal of Surgical Oncology},
year = {2025},
doi = {10.1016/j.ejso.2023.04.007}
}
EUVIMED