EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Utility of contrast-enhanced 3D STIR FLAIR imaging for evaluating pituitary adenomas at 3 Tesla

Iichiro Osawa, Keita Nagawa, Yuki Hara, Hirokazu Shimizu, Sayuri Tanaka, Eito Kozawa

European Journal of Radiology Open · 2023-12 · 11 · 100500

DOI: 10.1016/j.ejro.2023.100500 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Radiology Open, 2023-12. Verfasst von Iichiro Osawa und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Saitama Medical University Hospital, 38 Morohongo, Moroyama-machi, Iruma-gun, Saitama 350-0495, Japan. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To assess the usefulness of contrast-enhanced 3D STIR FLAIR imaging for evaluation of pituitary adenomas.

Methods

Patients with pituitary adenomas underwent MR examinations including contrast-enhanced 3D STIR FLAIR and 2D T1-weighted (T1W) imaging. We subjectively compared the two techniques in terms of 10 categories. In addition, images were rated by side-by-side comparisons into three outcomes: 3D STIR FLAIR imaging superior, equal, or 2D T1W imaging superior. Additionally, the added value of 3D STIR FLAIR imaging for adenoma detection over conventional MR imaging was assessed.

Results

Twenty-one patients were included in this study. 3D STIR FLAIR imaging offered significantly better images than 2D T1W imaging in terms of three categories, including overall visualization of the cranial nerves in the cavernous sinus (mean 4.0 vs. 2.8, p < 0.0001), visualization of the optic nerves and chiasm (mean 4.0 vs. 2.6, p < 0.0001), and severity of susceptibility artifacts (mean 0.0 vs. 0.4, p = 0.004). In the side-by-side comparison, 3D STIR FLAIR imaging was judged to be significantly superior to 2D T1W imaging for overall lesion conspicuity (62% vs. 19%, p = 0.049) and border between the adenoma and the pituitary gland (67% vs. 19%, p = 0.031). The addition of 3D STIR FLAIR imaging significantly improved the adenoma detection of conventional MR imaging.

Conclusion

3D STIR FLAIR imaging improved overall lesion conspicuity compared to 2D T1W imaging. We suggest that 3D STIR FLAIR imaging is recommended as a supplemental technique when pituitary adenomas are invisible or equivocal on conventional imaging.

Schlagwörter

Stichwörter der Autor:innen

3D STIR FLAIRMagnetic resonance imagingPituitary adenomaPituitary glandT1-weighted imaging

Autor:innen und Institutionen

  • Department of Radiology, Saitama Medical University Hospital, 38 Morohongo, Moroyama-machi, Iruma-gun, Saitama 350-0495, Japan.

Zitieren

APA

Osawa, I., Nagawa, K., Hara, Y., Shimizu, H., Tanaka, S., & Kozawa, E. (2023). Utility of contrast-enhanced 3D STIR FLAIR imaging for evaluating pituitary adenomas at 3 Tesla. European Journal of Radiology Open, 11, 100500. https://doi.org/10.1016/j.ejro.2023.100500

Vancouver

Osawa I, Nagawa K, Hara Y, Shimizu H, Tanaka S, Kozawa E. Utility of contrast-enhanced 3D STIR FLAIR imaging for evaluating pituitary adenomas at 3 Tesla. European Journal of Radiology Open. 2023;11:100500. doi:10.1016/j.ejro.2023.100500

BibTeX
@article{Osawa2023,
  author = {Osawa, Iichiro and Nagawa, Keita and Hara, Yuki and Shimizu, Hirokazu and Tanaka, Sayuri and Kozawa, Eito},
  title = {Utility of contrast-enhanced 3D STIR FLAIR imaging for evaluating pituitary adenomas at 3 Tesla},
  journal = {European Journal of Radiology Open},
  year = {2023},
  volume = {11},
  pages = {100500},
  doi = {10.1016/j.ejro.2023.100500}
}
Kostenlos starten →