EUVIMEDEUVIMED entdecken
Crossref

Measuring prostate cancer lesion size on serial MRI during active surveillance: A multi-centre observational study

Jina Pakpoor, Cameron Englman, Busola Adebusoye, Michele Cosenza, Andrea Del Prete, Louise Dickinson, Giulio Imperiale, Giorgio Gandaglia, Riccardo Leni, Francesco De Cobelli, Sue Mallett, Alexander Kirkham und 3 weitere

European Journal of Radiology · 2027-01 · 206 · 113233

DOI: 10.1016/j.ejrad.2026.113233 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Radiology, 2027-01. Verfasst von Jina Pakpoor und 14 weiteren Autor:innen. Beteiligte Einrichtung: Division of Surgery & Interventional Science, University College London, London, UK; Department of Radiology, University College London Hospitals NHS…. Die Arbeit nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To assess the intra- and inter-reader reliability of measurements of prostate cancer (PCa) lesions on serial multiparametric MRI scans, and to assess how lesion characteristics and measurement methods influence measurements over time in an international two-centre setting. MATERIALS AND METHODS: Twenty patients with low- or intermediate-risk PCa undergoing active surveillance were included. A total of three MRI scans were evaluated for each patient: one baseline and two serial follow-up scans. Five consultant radiologists from two institutions independently measured the size of the index lesion at each time point by four methods: maximum diameter, biaxial diameters, ellipsoid volume, and planimetry. Measurements were repeated after a four-week 'wash-out' period. Variability was assessed using strip plots and Bland-Altman analysis. RESULTS: Graphical presentation of inter-reader and intra-reader reliability enabled examination of variability between methods, readers and reads. Variability increased with lesion size and was greatest for lesions with poorly defined margins. Smaller, well-delineated lesions demonstrated greater consistency over time and across readers. Estimates of percentage change showed greater variability than absolute measurements, particularly for volumetric methods. Small differences in the underlying absolute measurements are amplified when expressed relative to baseline values. CONCLUSION: Serial MRI assessment of PCa lesion size is subject to substantial variability, particularly for larger lesions and lesions with indistinct boundaries. The benefits of consistent readers and measurement methods warrant further confirmation in larger prospective studies to support reliable clinical decision-making during active surveillance.

Schlagwörter

Stichwörter der Autor:innen

Active surveillanceInter-raterIntra-raterProstate cancerProstate magnetic resonance imagingReliability

Autor:innen und Institutionen

  • Division of Surgery & Interventional Science, University College London, London, UK; Department of Radiology, University College London Hospitals NHS Foundation Trust, London, UK. Electronic address: jina.pakpoor.25@ucl…
  • Division of Surgery & Interventional Science, University College London, London, UK; Department of Radiology, University College London Hospitals NHS Foundation Trust, London, UK.
  • Division of Surgery & Interventional Science, University College London, London, UK; Centre of Medical Imaging, Division of Medicine, University College London, London, UK.
  • Department of Radiology, IRCCS San Raffaele Scientific Institute, Milan, Italy; Vita-Salute San Raffaele University, Milan, Italy.
  • Department of Radiology, University College London Hospitals NHS Foundation Trust, London, UK.
  • Vita-Salute San Raffaele University, Milan, Italy; Division of Experimental Oncology, Department of Urology, IRCCS San Raffaele Scientific Institute, Milan, Italy.

Zitieren

APA

Pakpoor, J., Englman, C., Adebusoye, B., Cosenza, M., Prete, A. D., Dickinson, L., Imperiale, G., Gandaglia, G., Leni, R., Cobelli, F., Mallett, S., Kirkham, A., Moore, C. M., Giganti, F., & Brembilla, G. (2027). Measuring prostate cancer lesion size on serial MRI during active surveillance: A multi-centre observational study. European Journal of Radiology, 206, 113233. https://doi.org/10.1016/j.ejrad.2026.113233

Vancouver

Pakpoor J, Englman C, Adebusoye B, Cosenza M, Prete AD, Dickinson L, et al. Measuring prostate cancer lesion size on serial MRI during active surveillance: A multi-centre observational study. European Journal of Radiology. 2027;206:113233. doi:10.1016/j.ejrad.2026.113233

BibTeX
@article{Pakpoor2027,
  author = {Pakpoor, Jina and Englman, Cameron and Adebusoye, Busola and Cosenza, Michele and Prete, Andrea Del and Dickinson, Louise and Imperiale, Giulio and Gandaglia, Giorgio and Leni, Riccardo and Cobelli, Francesco De and Mallett, Sue and Kirkham, Alexander and Moore, Caroline M and Giganti, Francesco and Brembilla, Giorgio},
  title = {Measuring prostate cancer lesion size on serial MRI during active surveillance: A multi-centre observational study},
  journal = {European Journal of Radiology},
  year = {2027},
  volume = {206},
  pages = {113233},
  doi = {10.1016/j.ejrad.2026.113233}
}
Kostenlos starten →