Clinical quality of breath-held T1-weighted breast MRI in the supine position
European Journal of Radiology · 2026
DOI: 10.1016/j.ejrad.2026.112938 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Radiology, 2026. Verfasst von Judith Zimmermann und 8 weiteren Autor:innen. Beteiligte Einrichtung: Stanford University, Department of Radiology, Stanford, CA, USA. Electronic address: juzim@stanford.edu. Hauptthemen laut MEDLINE: Breast Neoplasms, Magnetic Resonance Imaging, Patient Positioning, Breath Holding. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NCATS NIH HHS, National Institute of Biomedical Imaging and Bioengineering, National Center for Advancing Translational Sciences.
Abstract (Originalsprache)
OBJECTIVE: Supine positioning for breast magnetic resonance imaging (MRI) may increase patient comfort, shorten exam times, improve co-registration with other modalities, and provide better guidance for surgical planning. The objective of this study was to assess the clinical quality of a breath-held T1-weighted sequence as a feasible approach for supine contrast-enhanced breast MRI. METHODS: At 3T, in 19 supine-positioned female breast cancer patients, we acquired a 3D T1-weighted Dixon gradient recalled echo sequence (LAVA), within ≤19s breath-hold to reduce respiratory motion, using a high-density body-conforming coil. The same subjects also underwent prone-positioned 3D T1-weighted Dixon breast MRI. Image quality was assessed by three radiologists, specifically regarding coverage, signal-to-noise, sharpness, and presence of artifacts. Reader scores were analyzed per reader with a proportion analysis. RESULTS: Supine LAVA images showed sufficient quality to be interpretable, with 97% 'diagnostic' scores, compared to also 97% for prone images. A high parallel imaging factor (12×) was necessary to achieve adequate combined bilateral breast and axillary lymph node coverage. CONCLUSION: The proposed sequence presents a viable option to acquire diagnostic quality supine-positioned contrast-enhanced T1-weighted bilateral breast images.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Stanford University, Department of Radiology, Stanford, CA, USA. Electronic address: juzim@stanford.edu.
- GE HealthCare, Aurora, OH, USA.
- Stanford University, Department of Radiology, Stanford, CA, USA.
- Stanford University, Department of Radiology, Stanford, CA, USA; Stanford University, Department of Bioengineering, Stanford, CA, USA.
- Stanford University, Department of Radiology, Stanford, CA, USA; Stanford University, Department of Bioengineering, Stanford, CA, USA; Stanford University, Department of Electrical Engineering, Stanford, CA, USA.
Förderung
- NCATS NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
- National Center for Advancing Translational Sciences
- GE Healthcare
- National Institutes of Health
- National Institutes of Health National Cancer Institute
Zitieren
APA
Zimmermann, J., Vincent, J., Poplack, S. P., Pittman, S. M., Dashevsky, B. Z., Zhou, X., Robb, F., Daniel, B. L., & Hargreaves, B. A. (2026). Clinical quality of breath-held T1-weighted breast MRI in the supine position. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2026.112938
Vancouver
Zimmermann J, Vincent J, Poplack SP, Pittman SM, Dashevsky BZ, Zhou X, et al. Clinical quality of breath-held T1-weighted breast MRI in the supine position. European Journal of Radiology. 2026. doi:10.1016/j.ejrad.2026.112938
BibTeX
@article{Zimmermann2026,
author = {Zimmermann, Judith and Vincent, Jana and Poplack, Steven P and Pittman, Sarah M and Dashevsky, Brittany Z and Zhou, Xuetong and Robb, Fraser and Daniel, Bruce L and Hargreaves, Brian A},
title = {Clinical quality of breath-held T1-weighted breast MRI in the supine position},
journal = {European Journal of Radiology},
year = {2026},
doi = {10.1016/j.ejrad.2026.112938}
}
EUVIMED