Mathematical fidelity vs. perceptual realism: A multi-center study of super-resolution radiomics for lung adenocarcinoma invasiveness
European Journal of Radiology · 2026-06 · 199 · 112794
DOI: 10.1016/j.ejrad.2026.112794 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift European Journal of Radiology, 2026-06. Verfasst von Mao-Tong Liu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Huadong Hospital, Fudan University, Shanghai 200040, PR China. Hauptthemen laut MEDLINE: Radiomics, Lung Neoplasms, Adenocarcinoma of Lung, Radiographic Image Interpretation, Computer-Assisted. Die Arbeit nennt 34 Literaturangaben. Gefördert von: National Science and Technology Major Project, Ministry of Science and Technology of the People's Republic of China.
Abstract (Originalsprache)
OBJECTIVE To identify the optimal super-resolution (SR) architecture for radiomics by comparing three models (Residual Channel Attention Network (RCAN), Real-Enhanced Super-Resolution Generative Adversarial Network (Real-ESRGAN), and Hybrid Attention Transformer (HAT)) in predicting lung adenocarcinoma (LUAD) invasiveness while systematically evaluating feature stability and clinical reliability. METHODS We retrospectively enrolled 373 LUAD patients across two centers (Approval: Huadong Hospital No. 20230051; Nantong Third People's Hospital No. EL2025021). Three SR models were fine-tuned on an in-house dataset (81,545 images) to generate SR images from original-resolution (OR) scans. We extracted 107 radiomic features and assessed fidelity across feature categories using the Clinical Concordance Coefficient (CCC) and Radiomic Feature Distance (RFD). Diagnostic performance across five machine learning classifiers was analyzed, with clinical reliability quantified by Brier scores. The best signature was validated against a clinical-only model. RESULTS Despite high perceptual quality, Real-ESRGAN exhibited catastrophic feature distortion (RFD > 300,000). RCAN achieved optimal stability, especially in first-order and texture categories (highest CCC: 0.779; lowest RFD: 9.02). RCAN achieved the highest diagnostic performance and stability (Mean AUC: 0.911 ± 0.008), significantly outperforming the OR baseline (0.875 ± 0.022; P = 0.043) with superior calibration (Brier score: 0.1766). Conversely, neither HAT (P = 0.628) nor Real-ESRGAN (P = 0.923) showed significant diagnostic improvement. Furthermore, the RCAN model significantly outperformed the clinical-only baseline (AUC: 0.924 vs. 0.837, P = 0.006). CONCLUSION The CNN-based RCAN outperforms generative and transformer architectures for quantitative radiomics. By prioritizing mathematical fidelity over perceptual realism, RCAN preserves signal integrity to ensure accurate and reliable LUAD risk stratification.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Huadong Hospital, Fudan University, Shanghai 200040, PR China.
- Department of Radiology, Affiliated Nantong Hospital 3 of Nantong University, 226000 Nantong, Jiangsu, PR China. Electronic address: ntsyzhangtao@sina.com.
- Department of Radiology, Huadong Hospital, Fudan University, Shanghai 200040, PR China. Electronic address: mingli19770506@163.com.
Förderung
- National Science and Technology Major Project
- Ministry of Science and Technology of the People's Republic of China
Zitieren
APA
Liu, M. T., Jin, L., Zhang, T., & Li, M. (2026). Mathematical fidelity vs. perceptual realism: A multi-center study of super-resolution radiomics for lung adenocarcinoma invasiveness. European Journal of Radiology, 199, 112794. https://doi.org/10.1016/j.ejrad.2026.112794
Vancouver
Liu MT, Jin L, Zhang T, Li M. Mathematical fidelity vs. perceptual realism: A multi-center study of super-resolution radiomics for lung adenocarcinoma invasiveness. European Journal of Radiology. 2026;199:112794. doi:10.1016/j.ejrad.2026.112794
BibTeX
@article{Liu2026,
author = {Liu, Mao-Tong and Jin, Liang and Zhang, Tao and Li, Ming},
title = {Mathematical fidelity vs. perceptual realism: A multi-center study of super-resolution radiomics for lung adenocarcinoma invasiveness},
journal = {European Journal of Radiology},
year = {2026},
volume = {199},
pages = {112794},
doi = {10.1016/j.ejrad.2026.112794}
}
EUVIMED