What proportion of patients undergoing fluoroscopy‑guided procedures and CT are alive or dead: 12-year study
European Journal of Radiology · 2026-06 · 199 · 112787
DOI: 10.1016/j.ejrad.2026.112787 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Radiology, 2026-06. Verfasst von Nasim Bazazzadeh und 2 weiteren Autor:innen. Beteiligte Einrichtung: Massachusetts General Hospital, Boston, MA, USA. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiography, Interventional. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: We evaluated long-term survival in patients undergoing fluoroscopy-guided procedures (FGPs), and CT over a 12-year period. METHODS: This retrospective study included 54,854 patients who underwent ≥ 1 FGP at a tertiary-care hospital from 2013 to 2022. Fluoroscopy dose was assessed using kerma-area-product (KAP), while CT dose was obtained from Radimetrics, which estimates organ and effective dose using Monte Carlo methods with ICRP 103 weighting factors. CED from fluoroscopy and CT were stratified into five dose groups (A: >0 to < 10 mSv, B: 10 to < 50 mSv, C: 50 to < 100 mSv, D: 100 to < 250 mSv, E: ≥250 mSv). Vital status and date of death were retrieved from the institutional registry through 2024. Mortality was evaluated at ≤ 5 years and ≤ 10 years following the first FGP. RESULTS: Overall, as of the end of December 2024, 45,765 patients (83.4%) were alive. Mortality proportions increased progressively from Groups A through E. Within Groups A-C, deceased patients were older than survivors (p < 0.001). Mean age at death decreased with dose, lowest in Group E (63.6 years). Mean CED was higher in deceased patients in Groups A-D (p < 0.001), but not in Group E (p = 0.224). CONCLUSIONS: Although early mortality in high-dose groups likely reflects underlying disease burden, many patients with CED ≥ 50-250 mSv survived 5-10 years and therefore remain at risk for late radiation effects. These findings emphasize the need for dose tracking, justification, and awareness of cumulative exposure in patients undergoing repeated imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Massachusetts General Hospital, Boston, MA, USA.
- Massachusetts General Hospital, Boston, MA, USA. Electronic address: mrehani@mgh.harvard.edu.
Zitieren
APA
Bazazzadeh, N., Kim, S. H., & Rehani, M. M. (2026). What proportion of patients undergoing fluoroscopy‑guided procedures and CT are alive or dead: 12-year study. European Journal of Radiology, 199, 112787. https://doi.org/10.1016/j.ejrad.2026.112787
Vancouver
Bazazzadeh N, Kim SH, Rehani MM. What proportion of patients undergoing fluoroscopy‑guided procedures and CT are alive or dead: 12-year study. European Journal of Radiology. 2026;199:112787. doi:10.1016/j.ejrad.2026.112787
BibTeX
@article{Bazazzadeh2026,
author = {Bazazzadeh, Nasim and Kim, Sophia Hahjean and Rehani, Madan M},
title = {What proportion of patients undergoing fluoroscopy‑guided procedures and CT are alive or dead: 12-year study},
journal = {European Journal of Radiology},
year = {2026},
volume = {199},
pages = {112787},
doi = {10.1016/j.ejrad.2026.112787}
}
EUVIMED