EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY 4.0

Assessing coronary in-stent restenosis using ultrahigh-resolution photon-counting detector CT: results from a two-center study

Bálint Szilveszter, Muhammad Taha Hagar, Péter Kulyassa, Barbara Sipos, Anikó Kubovje, Borbála Vattay, Melinda Boussoussou, Sámuel Beke, Kristóf Nagy, Lili Száraz, Pál Maurovich-Horvat, Akos Varga-Szemes und 2 weitere

European Journal of Radiology · 2026

DOI: 10.1016/j.ejrad.2026.112766 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift European Journal of Radiology, 2026. Verfasst von Bálint Szilveszter und 13 weiteren Autor:innen. Beteiligte Einrichtung: Semmelweis University Heart and Vascular Center, Városmajor Street 68., 1122 Budapest, Hungary. Electronic address: szilveszter.balint@semmelweis.hu. Hauptthemen laut MEDLINE: Stents, Coronary Restenosis, Coronary Angiography, Computed Tomography Angiography. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nemzeti Kutatási Fejlesztési és Innovációs Hivatal, European Commission, Nemzeti Kutatási, Fejlesztési és Innovaciós Alap.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: To assess the diagnostic accuracy of ultrahigh-resolution (UHR) photon-counting detector (PCD)-CT for detecting obstructive and non-obstructive coronary in-stent restenosis (ISR), using invasive coronary angiography (ICA) as the reference. METHODS: Consecutive patients with coronary stents who underwent clinically indicated coronary CT angiography (CCTA) on a dual-source PCD-CT were retrospectively identified from two academic centers. All UHR scans were reconstructed at 0.2 mm and 0.4 mm slice thickness, the latter served as an energy-integrating detector CT-like proxy. Series were assessed for the presence of non-obstructive (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

StentsCoronary RestenosisCoronary AngiographyComputed Tomography AngiographyHumansSensitivity and SpecificityReproducibility of ResultsFemaleAgedMaleRetrospective StudiesPhotonsTreatment Outcome

Stichwörter der Autor:innen

Coronary artery diseaseDiagnostic accuracyPhoton-counting CT detectorStent assessment

Autor:innen und Institutionen

  • Semmelweis University Heart and Vascular Center, Városmajor Street 68., 1122 Budapest, Hungary. Electronic address: szilveszter.balint@semmelweis.hu.
  • Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston 29425, SC, USA.
  • Semmelweis University Heart and Vascular Center, Városmajor Street 68., 1122 Budapest, Hungary.
  • Department of Radiology, Medical Imaging Centre, Semmelweis University, 2 Korányi Sándor St, 1083 Budapest, Hungary.
  • Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston 29425, SC, USA; Department of Radiology, Medical Imaging Centre, Semmelweis University, 2 Korányi Sándo…
  • Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston 29425, SC, USA; Department of Diagnostic and Interventional Radiology, University Medical Center of the…

Förderung

  • Nemzeti Kutatási Fejlesztési és Innovációs Hivatal
  • European Commission
  • Nemzeti Kutatási, Fejlesztési és Innovaciós Alap
  • Magyar Tudományos Akadémia
  • Semmelweis Egyetem

Zitieren

APA

Szilveszter, B., Hagar, M. T., Kulyassa, P., Sipos, B., Kubovje, A., Vattay, B., Boussoussou, M., Beke, S., Nagy, K., Száraz, L., Maurovich-Horvat, P., Varga-Szemes, A., Emrich, T., & Vecsey-Nagy, M. (2026). Assessing coronary in-stent restenosis using ultrahigh-resolution photon-counting detector CT: results from a two-center study. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2026.112766

Vancouver

Szilveszter B, Hagar MT, Kulyassa P, Sipos B, Kubovje A, Vattay B, et al. Assessing coronary in-stent restenosis using ultrahigh-resolution photon-counting detector CT: results from a two-center study. European Journal of Radiology. 2026. doi:10.1016/j.ejrad.2026.112766

BibTeX
@article{Szilveszter2026,
  author = {Szilveszter, Bálint and Hagar, Muhammad Taha and Kulyassa, Péter and Sipos, Barbara and Kubovje, Anikó and Vattay, Borbála and Boussoussou, Melinda and Beke, Sámuel and Nagy, Kristóf and Száraz, Lili and Maurovich-Horvat, Pál and Varga-Szemes, Akos and Emrich, Tilman and Vecsey-Nagy, Milán},
  title = {Assessing coronary in-stent restenosis using ultrahigh-resolution photon-counting detector CT: results from a two-center study},
  journal = {European Journal of Radiology},
  year = {2026},
  doi = {10.1016/j.ejrad.2026.112766}
}
Kostenlos starten →