A comprehensive quantitative and qualitative assessment of TGSE-BLADE DWI in postoperative imaging following intracranial tumor resection
European Journal of Radiology · 2026
DOI: 10.1016/j.ejrad.2026.112659 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Radiology, 2026. Verfasst von Christer Ruff und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls-University Tuebingen, Tuebingen D-72076, Germany. Electronic address: chri…. Hauptthemen laut MEDLINE: Brain Neoplasms, Diffusion Magnetic Resonance Imaging, Image Interpretation, Computer-Assisted. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
PURPOSE: Postoperative MRI plays a pivotal role in assessing residual disease and planning therapy after intracranial tumor resection. As acute perioperative infarction may mimic enhancing and non-enhancing tumor tissue in follow-up imaging, the initial postoperative MRI examination is essential for this purpose. However, conventional DWI techniques like RESOLVE are often impaired by artifacts from intracranial air. This study compares RESOLVE DWI with TGSE-BLADE DWI within early postoperative scans to improve diagnostic confidence in identifying ischemic changes. METHOD: In a retrospective, institutional review board-approved study, 33 patients (mean age 52.3 ± 25.1 years) underwent a 1.5-Tesla MRI within 48 h of resection. RESOLVE and TGSE-BLADE DWI sequences were acquired in the same orientation and slice thickness of 5 mm. Two neuroradiologists blindly evaluated geometric distortion, susceptibility artifacts, overall image quality, and diagnostic confidence. Quantitative analysis included measuring signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), apparent diffusion coefficient (ADC) values, image quality metrics and resection defect dimensions against T1-weighted images. RESULTS: TGSE-BLADE DWI exhibited significantly reduced geometric distortions and susceptibility artifacts near the resection site compared with RESOLVE DWI, producing superior qualitative image quality and diagnostic confidence (p < 0.001). Conversely, RESOLVE DWI yielded slightly higher SNR and CNR. Measurements of the resection defect on TGSE-BLADE DWI closely matched those on T1-weighted images (p = 0.974), while RESOLVE DWI showed a significant discrepancy (p < 0.001). CONCLUSIONS: TGSE-BLADE DWI significantly minimizes artifacts and geometric distortions in intracranial postoperative imaging, thereby improving the detection of perioperative ischemic changes. This robust technique serves as an effective alternative to conventional EPI-based sequences in challenging settings with pronounced B0 inhomogeneities, ultimately enhancing diagnostic confidence and patient care.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls-University Tuebingen, Tuebingen D-72076, Germany. Electronic address: christer.ruff@med.uni-tuebingen.de.
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls-University Tuebingen, Tuebingen D-72076, Germany.
- Department of Neurology and Interdisciplinary Neuro-Oncology, University Hospital Tuebingen, Tuebingen D-72076, Germany; Hertie Institute for Clinical Brain Research, Eberhard Karls University Tuebingen Center of Neuro-…
- Department of Neurosurgery, University of Tuebingen, Tuebingen D-72076, Germany.
- Center for Neuro-Oncology, Comprehensive Cancer Center Tuebingen-Stuttgart, University Hospital of Tuebingen, Eberhard Karls University of Tuebingen, Tuebingen D-72070, Germany; Department of Neurosurgery, University of…
- Department of Radiation Oncology, University Hospital Tuebingen, Tuebingen D-72076, Germany.
Zitieren
APA
Ruff, C., Hauser, T. K., Bombach, P., Vogl, D., Roder, C., Paulsen, F., Staber, D., Richter, V., Zerweck, L., Ernemann, U., & Gohla, G. (2026). A comprehensive quantitative and qualitative assessment of TGSE-BLADE DWI in postoperative imaging following intracranial tumor resection. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2026.112659
Vancouver
Ruff C, Hauser TK, Bombach P, Vogl D, Roder C, Paulsen F, et al. A comprehensive quantitative and qualitative assessment of TGSE-BLADE DWI in postoperative imaging following intracranial tumor resection. European Journal of Radiology. 2026. doi:10.1016/j.ejrad.2026.112659
BibTeX
@article{Ruff2026,
author = {Ruff, Christer and Hauser, Till-Karsten and Bombach, Paula and Vogl, Daniel and Roder, Constantin and Paulsen, Frank and Staber, Deborah and Richter, Vivien and Zerweck, Leonie and Ernemann, Ulrike and Gohla, Georg},
title = {A comprehensive quantitative and qualitative assessment of TGSE-BLADE DWI in postoperative imaging following intracranial tumor resection},
journal = {European Journal of Radiology},
year = {2026},
doi = {10.1016/j.ejrad.2026.112659}
}
EUVIMED