EUVIMEDEUVIMED entdecken
Crossref

Robotic navigation-assisted radio-frequency ablation of lung tumors: a pilot study

Yi Fang, Milan Sigdel, Manoj Sigdel, Madan Sigdel, Roshan Bhattarai, Mikias Legesse Gebremedhin, Zhanguo Sun, Xinwei Han, Dechao Jiao

European Journal of Radiology · 2026

DOI: 10.1016/j.ejrad.2026.112655 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Radiology, 2026. Verfasst von Yi Fang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China. Hauptthemen laut MEDLINE: Lung Neoplasms, Robotic Surgical Procedures, Catheter Ablation, Radiofrequency Ablation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: Major Science and Technology Projects in Yunnan Province, Henan Provincial Science and Technology Research Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the feasibility and safety of percutaneous radiofrequency ablation (RFA) of lung tumors under the guidance of robotic navigation system. MATERIAL AND METHODS: From January 2022 to December 2023, 62 cases with solitary lung tumors who underwent RFA procedure at our department and were divided into two groups: the robotic navigation assisted puncture (RNAP) group (n = 26) and manual puncture (MP) group (n = 36). Two groups were compared in terms of technical success (TS), puncture scoring (PS), CT scan times, Total procedure time (TPT), puncture time (PT), radiation exposure (RE), complete ablation (CA) rate and local tumor progression rate (LTP) rate. RESULTS: PS, PT, total number of CT scans, and RE showed significance between patients in the RNAP compared to those in the MP group (15/8/2/1 vs. 6/8/18/4, P = 0.05). CONCLUSIONS: Robotic navigation-assisted radiofrequency ablation of lung tumors is a feasible and safe technique. It can minimize needle adjustments, thereby shortening puncture time and reducing radiation exposure for patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lung NeoplasmsRobotic Surgical ProceduresCatheter AblationRadiofrequency AblationHumansPilot ProjectsFemaleMaleTreatment OutcomeMiddle AgedAgedTomography, X-Ray ComputedFeasibility Studies

Stichwörter der Autor:innen

AblationLung tumorsMinimally invasive therapyPercutaneous punctureRobotic navigation

Autor:innen und Institutionen

  • Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
  • Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China; Galaxy Hospital, Pokhara, Nepal.
  • Faculty of Health Sciences, Pokhara University, Pokhara, Nepal.
  • Tribhuvan University, Kirtipur, Nepal.
  • Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China. Electronic address: jiaodechao007@126.com.

Förderung

  • Major Science and Technology Projects in Yunnan Province
  • Henan Provincial Science and Technology Research Project

Zitieren

APA

Fang, Y., Sigdel, M., Sigdel, M., Sigdel, M., Bhattarai, R., Gebremedhin, M. L., Sun, Z., Han, X., & Jiao, D. (2026). Robotic navigation-assisted radio-frequency ablation of lung tumors: a pilot study. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2026.112655

Vancouver

Fang Y, Sigdel M, Sigdel M, Sigdel M, Bhattarai R, Gebremedhin ML, et al. Robotic navigation-assisted radio-frequency ablation of lung tumors: a pilot study. European Journal of Radiology. 2026. doi:10.1016/j.ejrad.2026.112655

BibTeX
@article{Fang2026,
  author = {Fang, Yi and Sigdel, Milan and Sigdel, Manoj and Sigdel, Madan and Bhattarai, Roshan and Gebremedhin, Mikias Legesse and Sun, Zhanguo and Han, Xinwei and Jiao, Dechao},
  title = {Robotic navigation-assisted radio-frequency ablation of lung tumors: a pilot study},
  journal = {European Journal of Radiology},
  year = {2026},
  doi = {10.1016/j.ejrad.2026.112655}
}
Kostenlos starten →