EUVIMEDEUVIMED entdecken
Crossref

Usefulness of metal artifact reduction on CT angiography after massive coil embolization in peripheral AVM

Jihwan Choi, Sang Yub Lee, Kwang Bo Park, Joon Kee Park, Shin Seok Yang, Chang Hoon Oh, Taejun Jeon, Dong-Ik Kim, Young Soo Do

European Journal of Radiology · 2026

DOI: 10.1016/j.ejrad.2025.112606 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Radiology, 2026. Verfasst von Jihwan Choi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Digital Health, SAIHST, Sungkyunkwan University, 115 Irwon-Ro, Gangnam-gu, Seoul, the Republic of Korea; Department of Radiology, Samsu…. Hauptthemen laut MEDLINE: Artifacts, Embolization, Therapeutic, Metals, Computed Tomography Angiography. Die Arbeit nennt 35 Literaturangaben. Gefördert von: Samsung Medical Center, Sungkyunkwan University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the image quality of three reconstruction methods-filtered back projection (FBP), adaptive statistical iterative reconstruction (AR50), and deep learning-based reconstruction (DL-M)-processed with the Smart Metal Artifact Reduction (SMAR) technique for post-embolization assessment of peripheral arteriovenous malformations (AVMs). MATERIALS AND METHODS: In this prospective single-center study, 30 patients who underwent coil embolization for AVM were included. Post-embolization CT angiography was performed using dual-energy CT. Virtual monoenergetic images at 50 and 70 keV were reconstructed using FBP, AR50, and DL-M. All were processed with SMAR, and DL-M without SMAR served as the baseline. Artifact severity was objectively assessed using the standard deviation (SD) around the AVM, artifact index (AI), and contrast-to-noise ratio (CNR). Two readers (a resident and a staff radiologist) subjectively graded artifact severity, vessel visualization, and new artifacts using 4-point scales. RESULTS: At both energy levels, average SD and AI were significantly lower in SMAR-processed images than in baseline DL-M (all p < 0.001). Subjective scores for artifact reduction and visualization of adjacent vessels were also significantly improved (p < 0.001). There were no significant differences among the three SMAR-processed methods. New artifacts appeared in three cases but had minimal effect on interpretability. CONCLUSIONS: SMAR-processed FBP, AR50, and DL-M reconstructions significantly reduced metal artifacts and improved visualization after AVM coil embolization, supporting their value for post-treatment evaluation and clinical decision-making.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsEmbolization, TherapeuticMetalsComputed Tomography AngiographyArteriovenous MalformationsHumansMaleFemaleMiddle AgedAdultProspective StudiesRadiographic Image Interpretation, Computer-AssistedAgedYoung AdultAdolescent

Stichwörter der Autor:innen

Arteriovenous malformationArtifactEmbolization, therapeuticImage processing, computer-assistedTomography, X-ray computed

Substanzen

Metals

Autor:innen und Institutionen

  • Department of Digital Health, SAIHST, Sungkyunkwan University, 115 Irwon-Ro, Gangnam-gu, Seoul, the Republic of Korea; Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul,…
  • Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, the Republic of Korea. Electronic address: sangyubir.lee@samsung.com.
  • Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, the Republic of Korea.
  • Division of Vascular Surgery, Department of Surgery, Samsung Medical Center, Sungkyunkwan Univeristy School of Medicine, the Republic of Korea.
  • Department of Radiology, Hallym University Sacred Heart Hospital, Anyang, the Republic of Korea.

Förderung

  • Samsung Medical Center, Sungkyunkwan University

Zitieren

APA

Choi, J., Lee, S. Y., Park, K. B., Park, J. K., Yang, S. S., Oh, C. H., Jeon, T., Kim, D. I., & Do, Y. S. (2026). Usefulness of metal artifact reduction on CT angiography after massive coil embolization in peripheral AVM. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2025.112606

Vancouver

Choi J, Lee SY, Park KB, Park JK, Yang SS, Oh CH, et al. Usefulness of metal artifact reduction on CT angiography after massive coil embolization in peripheral AVM. European Journal of Radiology. 2026. doi:10.1016/j.ejrad.2025.112606

BibTeX
@article{Choi2026,
  author = {Choi, Jihwan and Lee, Sang Yub and Park, Kwang Bo and Park, Joon Kee and Yang, Shin Seok and Oh, Chang Hoon and Jeon, Taejun and Kim, Dong-Ik and Do, Young Soo},
  title = {Usefulness of metal artifact reduction on CT angiography after massive coil embolization in peripheral AVM},
  journal = {European Journal of Radiology},
  year = {2026},
  doi = {10.1016/j.ejrad.2025.112606}
}
Kostenlos starten →