Potential for AI as first reader in lung cancer screening
European Journal of Radiology · 2026-02 · 195 · 112561
DOI: 10.1016/j.ejrad.2025.112561 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Radiology, 2026-02. Verfasst von Roberta Eufrasia Ledda und 9 weiteren Autor:innen. Beteiligte Einrichtung: Thoracic Surgery Unit, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy; Department of Medicine and Surgery (DiMeC), University of Parma,…. Hauptthemen laut MEDLINE: Lung Neoplasms, Tomography, X-Ray Computed, Artificial Intelligence, Early Detection of Cancer. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Cancer Institute, Ministero della Salute, Associazione Italiana per la Ricerca sul Cancro.
Abstract (Originalsprache)
PURPOSE: To retrospectively assess the agreement between human and automated AI-based readings for low-dose computed tomography (LDCT) outcomes according to LungRADS v1.1 in lung cancer screening (LCS); to test the diagnostic performance of both readings. METHODS: We included 4104 baseline LDCTs from the BioMILD trial. Original readings were retrospectively classified into "negative" (LungRADSv1.1 categories 1, 2) and "positive" (categories 3, 4) by a radiologist and analyzed by AI software for category assignment. Diagnosis of lung cancer (LC) at 2 years served as reference standard to assess sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) of both human and AI. Agreement between readers was measured by the k-Cohen Index with Fleiss-Cohen weights (Kw) with 95 % CI. RESULTS: Median age of participants was 60 years; 60.8 % were male and 79.2 % current smokers; 68/4104 (1.7 %) were diagnosed with LC; 6/68 (8.8 %) and 7/68 (10.3 %) LDCT were classified as negative by AI and human reading, respectively. The agreement between human and AI readings for negative and positive LDCTs was 83.5 % (Kw 0.47; 95 %CI: 0.43-0.50). Sensitivity and specificity were 91.2 % and 75.7 % for AI, and 89.7 % and 90.0 % for human reading (p-value 0.5637 and < 0.0001). PPV and NPV were 6.0 % and 99.8 % for AI, and 13.1 % and 99.8 % for human reading (p-value < 0.0001 and 0.9351). The expected reduction in LDCT reading workload when using AI as first reader was 74.7 %. CONCLUSION: AI reading showed comparable sensitivity but lower specificity than human reading. High NPV of AI may support its use as a first reader in LCS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Thoracic Surgery Unit, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy; Department of Medicine and Surgery (DiMeC), University of Parma, Parma, Italy. Electronic address: robertaeufrasia.ledda@unipr.it.
- Thoracic Surgery Unit, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy. Electronic address: valsecchi.18@gmail.com.
- Thoracic Surgery Unit, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy. Electronic address: federica.sabia@istitutotumori.mi.it.
- Department of Medicine and Surgery (DiMeC), University of Parma, Parma, Italy. Electronic address: gianluca.milanese@unipr.it.
- Radiology Unit, San Luigi Gonzaga Hospital, Department of Oncology, University of Turin, Orbassano TO, Italy. Electronic address: maurizio.balbi@unito.it.
- Thoracic Surgery Unit, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy. Electronic address: luigi.rolli@istitutotumori.mi.it.
Förderung
- National Cancer Institute
- Ministero della Salute
- Associazione Italiana per la Ricerca sul Cancro
Zitieren
APA
Ledda, R. E., Valsecchi, C., Sabia, F., Milanese, G., Balbi, M., Rolli, L., Ruggirello, M., Sverzellati, N., Marchianò, A. V., & Pastorino, U. (2026). Potential for AI as first reader in lung cancer screening. European Journal of Radiology, 195, 112561. https://doi.org/10.1016/j.ejrad.2025.112561
Vancouver
Ledda RE, Valsecchi C, Sabia F, Milanese G, Balbi M, Rolli L, et al. Potential for AI as first reader in lung cancer screening. European Journal of Radiology. 2026;195:112561. doi:10.1016/j.ejrad.2025.112561
BibTeX
@article{Ledda2026,
author = {Ledda, Roberta Eufrasia and Valsecchi, Camilla and Sabia, Federica and Milanese, Gianluca and Balbi, Maurizio and Rolli, Luigi and Ruggirello, Margherita and Sverzellati, Nicola and Marchianò, Alfonso Vittorio and Pastorino, Ugo},
title = {Potential for AI as first reader in lung cancer screening},
journal = {European Journal of Radiology},
year = {2026},
volume = {195},
pages = {112561},
doi = {10.1016/j.ejrad.2025.112561}
}
EUVIMED