Comparison of precise imaging and iterative reconstruction techniques at low doses using the dose right index in 100-kVp cerebral CT angiography
European Journal of Radiology · 2026-01 · 194 · 112504
DOI: 10.1016/j.ejrad.2025.112504 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift European Journal of Radiology, 2026-01. Verfasst von Imnejongla Chang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India. Electronic addr…. Hauptthemen laut MEDLINE: Radiation Dosage, Computed Tomography Angiography, Cerebral Angiography, Radiographic Image Interpretation, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Manipal Academy of Higher Education.
Abstract (Originalsprache)
BACKGROUND: Artificial intelligence (AI)-driven image reconstruction has shown potential for enhancing image quality in CT angiography while reducing radiation exposure. However, reproducibility and methodological transparency are essential for real-world adoption. PURPOSE: To compare image quality and radiation dose of cerebral CT angiography reconstructed with conventional iterative reconstruction (IR) and AI-based Precise Imaging (PI) at 100 kVp using a reduced Dose Right Index (DRI-15). METHODS: In this prospective single-center study, 68 patients underwent 100 kVp cerebral CT angiography with a 50% reduced Dose Right Index (DRI-15 vs. DRI-36). Identical raw datasets were reconstructed using IR (iDose4) and PI. Quantitative analysis included attenuation, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR), while two blinded radiologists independently performed qualitative assessment using a 5-point Likert scale. Radiation dose metrics (CTDIvol, DLP, effective dose) were recorded. Standardized acquisition protocols, fixed contrast injection, and consistent ROI placement ensured reproducibility. RESULTS: PI reconstructions yielded significantly lower noise and higher SNR and CNR than IR (all p < 0.001; r = 0.61-0.71), with no difference in vascular attenuation (p = 0.118). Qualitative scores were superior for PI across all criteria (p < 0.01), while inter-rater agreement was substantial for both methods, slightly higher with IR. The median effective dose was 0.785 mSv (IQR 0.71-0.90). CONCLUSION: AI-based PI reconstruction enhances image quality without increasing radiation dose or altering vascular attenuation, consistently outperforming IR and supporting its use in low-dose cerebral CT angiography, especially in dose-sensitive patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India. Electronic address: imnejongla.mchpmpl2023@learner.manipal.edu.
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India. Electronic address: abhimanyu.pradhan@manipal.edu.
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India. Electronic address: sharath.s@manipal.edu.
- Department of Radiodiagnosis and Imaging, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, India. Electronic address: rajagopal.kv@manipal.edu.
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India. Electronic address: winniecia.dkhar@manipal.edu.
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India. Electronic address: suresh.sugumar@manipal.edu.
Förderung
- Manipal Academy of Higher Education
Zitieren
APA
Chang, I., Pradhan, A., S, S., Kadavigere, R., Dkhar, W., Sukumar, S., Prabhu, A., & Barnes, N. A. (2026). Comparison of precise imaging and iterative reconstruction techniques at low doses using the dose right index in 100-kVp cerebral CT angiography. European Journal of Radiology, 194, 112504. https://doi.org/10.1016/j.ejrad.2025.112504
Vancouver
Chang I, Pradhan A, S S, Kadavigere R, Dkhar W, Sukumar S, et al. Comparison of precise imaging and iterative reconstruction techniques at low doses using the dose right index in 100-kVp cerebral CT angiography. European Journal of Radiology. 2026;194:112504. doi:10.1016/j.ejrad.2025.112504
BibTeX
@article{Chang2026,
author = {Chang, Imnejongla and Pradhan, Abhimanyu and S, Sharath and Kadavigere, Rajagopal and Dkhar, Winniecia and Sukumar, Suresh and Prabhu, Ashwin and Barnes, Neil Abraham},
title = {Comparison of precise imaging and iterative reconstruction techniques at low doses using the dose right index in 100-kVp cerebral CT angiography},
journal = {European Journal of Radiology},
year = {2026},
volume = {194},
pages = {112504},
doi = {10.1016/j.ejrad.2025.112504}
}
EUVIMED