Improved accuracy of bone marrow edema detection in patients with hip pain using dual-energy computed tomography: Optimization of blended material density images combining water-calcium and water-hydroxyapatite
European Journal of Radiology · 2025
DOI: 10.1016/j.ejrad.2025.112293 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Radiology, 2025. Verfasst von Kosuke Yoshii und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Hyogo Prefectural Kakogawa Medical Center, 203 Kannocho, Kanno, Kakogawa, Hyogo 675-8555, Japan; Department of Radiation Tec…. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Edema, Bone Marrow Diseases, Radiography, Dual-Energy Scanned Projection. Die Arbeit nennt 26 Literaturangaben.
Abstract (Originalsprache)
RATIONALE AND OBJECTIVES: This study aimed to optimize newly developed blended material density (MD) images, compare them with conventional water-calcium (Ca) and water-hydroxyapatite (HAP) images, and identify the most suitable MD images for detecting bone marrow edema (BME). MATERIALS AND METHODS: We retrospectively analyzed the data of 24 patients (47 hips) who underwent dual-energy computed tomography (DECT) and magnetic resonance imaging (MRI) within one week of experiencing hip pain between April 2022 and March 2024. DECT was performed using a single-source fast-kV switching system and two material decomposition algorithms to generate 9 blended MD images by adjusting the mixing ratios of water-Ca and water-HAP (water-9Ca:1HAP to water-1Ca:9HAP). The optimal blended MD image was identified using the area under the curve (AUC) from the receiver operating characteristic (ROC) analysis. Radiologists and orthopedic surgeons visually assessed the concordance between the three types of MD images and MRI findings using a five-point scale. RESULTS: Among the 24 patients, 19 (79.2 %) were diagnosed with BME through MRI. Among the blended MD images, water-2Ca:8HAP demonstrated the highest diagnostic accuracy (AUC: 0.980), significantly outperforming water-Ca (AUC: 0.909, P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Hyogo Prefectural Kakogawa Medical Center, 203 Kannocho, Kanno, Kakogawa, Hyogo 675-8555, Japan; Department of Radiation Technology, Hyogo Ion Beam Medical Center, 1-2-1, Shingucho Koto, Tatsuno…
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan.
- Department of Radiology, Hyogo Prefectural Kakogawa Medical Center, 203 Kannocho, Kanno, Kakogawa, Hyogo 675-8555, Japan.
- Department of Radiology and Interventional Radiology, Hyogo Prefectural Kakogawa Medical Center, 203 Kannocho, Kanno, Kakogawa, Hyogo 675-8555, Japan.
- Department of Orthopaedic Surgery, Hyogo Prefectural Kakogawa Medical Center, 203 Kannocho, Kanno, Kakogawa, Hyogo 675-8555, Japan.
Zitieren
APA
Yoshii, K., Masuda, T., Tanaka, S., Sanda, Y., & Takahara, S. (2025). Improved accuracy of bone marrow edema detection in patients with hip pain using dual-energy computed tomography: Optimization of blended material density images combining water-calcium and water-hydroxyapatite. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2025.112293
Vancouver
Yoshii K, Masuda T, Tanaka S, Sanda Y, Takahara S. Improved accuracy of bone marrow edema detection in patients with hip pain using dual-energy computed tomography: Optimization of blended material density images combining water-calcium and water-hydroxyapatite. European Journal of Radiology. 2025. doi:10.1016/j.ejrad.2025.112293
BibTeX
@article{Yoshii2025,
author = {Yoshii, Kosuke and Masuda, Takanori and Tanaka, Shinichi and Sanda, Yuki and Takahara, Shunsuke},
title = {Improved accuracy of bone marrow edema detection in patients with hip pain using dual-energy computed tomography: Optimization of blended material density images combining water-calcium and water-hydroxyapatite},
journal = {European Journal of Radiology},
year = {2025},
doi = {10.1016/j.ejrad.2025.112293}
}
EUVIMED