Assessment of biventricular cardiac function using free-breathing artificial intelligence cine with motion correction: Comparison with standard multiple breath-holding cine

Lingping Ran, Xianghu Yan, Yun Zhao, Zhaoxia Yang, Zihao Chen, Fenggang Jia, Xiaopeng Song, Lu Huang, Liming Xia

European Journal of Radiology · 2025

DOI: 10.1016/j.ejrad.2025.112133 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift European Journal of Radiology, 2025. Verfasst von Lingping Ran und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Cine, Artificial Intelligence, Image Interpretation, Computer-Assisted. Die Arbeit nennt 40 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To assess the image quality and biventricular function utilizing a free-breathing artificial intelligence cine method with motion correction (FB AI MOCO). METHODS: A total of 72 participants (mean age 38.3 ± 15.4 years, 40 males) prospectively enrolled in this single-center, cross-sectional study underwent cine scans using standard breath-holding (BH) cine and FB AI MOCO cine at 3.0 Tesla. The image quality of the cine images was evaluated with a 5-point Ordinal Likert scale based on blood-pool to myocardium contrast, endocardial edge definition, and artifacts, and overall quality score was calculated by the equal weight average of all three criteria, apparent signal to noise ratio (aSNR), estimated contrast to noise ratio (eCNR) were assessed. Biventricular functional parameters including Left Ventricular (LV), Right Ventricular (RV) End-Diastolic Volume (EDV), End-Systolic Volume (ESV), Stroke Volume (SV), Ejection Fraction (EF), and LV End-Diastolic Mass (LVEDM) were also assessed. Comparison between two sequences was assessed using paired t-test and Wilcoxon signed-rank test, correlation using Pearson correlation. The agreement of quantitative parameters was assessed using intraclass correlation coefficient (ICC) and Bland-Altman analysis. P 0.900) and excellent agreement (ICC > 0.900) were found for all biventricular functional parameters between the two sequences. In subgroups with reduced LVEF ( 0.05 for all) between the two sequences. CONCLUSION: In comparison to multiple BH cine, the FB AI MOCO cine achieved comparable image quality and biventricular functional parameters with shorter scan times, suggesting its promising potential for clinical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance Imaging, CineArtificial IntelligenceImage Interpretation, Computer-AssistedHumansMaleFemaleBreath HoldingAdultCross-Sectional StudiesArtifactsReproducibility of ResultsProspective StudiesMiddle AgedMotionSensitivity and Specificity

Stichwörter der Autor:innen

Artificial intelligenceCardiacCineFree-breathingMagnetic resonance imaging

Autor:innen und Institutionen

  • Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
  • University of California, Los Angeles, CA, USA.
  • Central Research Institute, United Imaging Healthcare, Shanghai, China.
  • Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China. Electronic address: tj_lhuang@hust.edu.cn.
  • Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China. Electronic address: lmxia@tjh.tjmu.edu.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Ran, L., Yan, X., Zhao, Y., Yang, Z., Chen, Z., Jia, F., Song, X., Huang, L., & Xia, L. (2025). Assessment of biventricular cardiac function using free-breathing artificial intelligence cine with motion correction: Comparison with standard multiple breath-holding cine. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2025.112133

Vancouver

Ran L, Yan X, Zhao Y, Yang Z, Chen Z, Jia F, et al. Assessment of biventricular cardiac function using free-breathing artificial intelligence cine with motion correction: Comparison with standard multiple breath-holding cine. European Journal of Radiology. 2025. doi:10.1016/j.ejrad.2025.112133

BibTeX
@article{Ran2025,
  author = {Ran, Lingping and Yan, Xianghu and Zhao, Yun and Yang, Zhaoxia and Chen, Zihao and Jia, Fenggang and Song, Xiaopeng and Huang, Lu and Xia, Liming},
  title = {Assessment of biventricular cardiac function using free-breathing artificial intelligence cine with motion correction: Comparison with standard multiple breath-holding cine},
  journal = {European Journal of Radiology},
  year = {2025},
  doi = {10.1016/j.ejrad.2025.112133}
}
Kostenlos starten →