High-resolution diffusion-weighted MRI plus mammography for detecting clinically occult breast cancers in women with dense breasts
European Journal of Radiology · 2024
DOI: 10.1016/j.ejrad.2024.111440 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Radiology, 2024. Verfasst von Hee Jeong Kim und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Breast Neoplasms, Mammography, Diffusion Magnetic Resonance Imaging, Sensitivity and Specificity. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 43 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To compare the performance of mammography, high-resolution DW-MRI, DCE-MRI, and their combinations in detecting clinically occult breast cancer in women with dense breasts. METHOD: 544 breasts from 281 consecutive asymptomatic women with dense breasts were retrospectively identified. They underwent breast MRI for preoperative evaluation of breast cancers (n = 214) or as supplemental screening (n = 67) including DCE-MRI and DW-MRI (b values, 0 and 1000 sec/mm2; in-plane resolution, 1.1 × 1.1 mm2 and 1.3 × 1.3 mm2; section thickness, 3 mm), in addition to mammography. Three readers independently reviewed each examination on a per-breast basis. Histopathology and at least two year of imaging follow-up served as the gold standard. The sensitivities and specificities of different imaging modalities were compared using McNemar test. RESULTS: 230 of 544 breasts (42 %) had malignant lesions. The sensitivity of DW-MRI was higher than that of mammography (77.0 % vs 57.9 %; adjusted p 0.999) and DCE-MRI (97.1 %; adjusted p > 0.999). DW-MRI plus mammography had a comparable sensitivity and specificity to those of DCE-MRI plus mammography (88.6 % vs 90.9 % and 97.1 % vs 96.2 %; adjusted p > 0.999 for both). CONCLUSIONS: High-resolution DW-MRI had a sensitivity higher than mammography and lower than DCE-MRI. Nevertheless, DW-MRI plus mammography showed a comparable sensitivity and specificity to DCE-MRI plus mammography for detecting clinically occult cancers in women with dense breasts.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea. Electronic address: docshin@amc.seoul.kr.
- Department of Clinical Epidemiology and Biostatistics, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.
- Department of Radiology, Gangdong Seongsim Byeongwon, University of Hallym College of Medicine, Seoul, Republic of Korea.
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea.
Zitieren
APA
Kim, H. J., Shin, H. J., Baek, S., Lee, C. W., Choi, W. J., Chae, E. Y., Cha, J. H., Kim, H. H., & Moon, W. K. (2024). High-resolution diffusion-weighted MRI plus mammography for detecting clinically occult breast cancers in women with dense breasts. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2024.111440
Vancouver
Kim HJ, Shin HJ, Baek S, Lee CW, Choi WJ, Chae EY, et al. High-resolution diffusion-weighted MRI plus mammography for detecting clinically occult breast cancers in women with dense breasts. European Journal of Radiology. 2024. doi:10.1016/j.ejrad.2024.111440
BibTeX
@article{Kim2024,
author = {Kim, Hee Jeong and Shin, Hee Jung and Baek, Seunghee and Lee, Chae Woon and Choi, Woo Jung and Chae, Eun Young and Cha, Joo Hee and Kim, Hak Hee and Moon, Woo Kyung},
title = {High-resolution diffusion-weighted MRI plus mammography for detecting clinically occult breast cancers in women with dense breasts},
journal = {European Journal of Radiology},
year = {2024},
doi = {10.1016/j.ejrad.2024.111440}
}
EUVIMED