EUVIMEDEUVIMED entdecken
Crossref

Improving prefilled syringe injectability: influences of critical component attributes and human factors

Yunyun Wang, Hui Li, Linke Wu, Zhixin Zhao, Quanmin Chen, Jeremy Guo

European Journal of Pharmaceutics and Biopharmaceutics · 2025-12 · 217 · 114901

DOI: 10.1016/j.ejpb.2025.114901 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Pharmaceutics and Biopharmaceutics, 2025-12. Verfasst von Yunyun Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Drug Product Development, WuXi Biologics, No. 1951 Huifeng West Rd., 201401 Shanghai City, China. Hauptthemen laut MEDLINE: Syringes. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Prefilled syringes (PFSs) have emerged as a predominant primary packaging format for subcutaneous biopharmaceutical drug products. Subcutaneous administration typically requires low injection volumes and high drug concentrations, which frequently leads to a nonlinear increase in viscosity; that can impair injectability and feasibility for patient self-administration, potentially affecting drug safety and efficacy. This research investigates critical PFS design elements (including silicone oil coating, barrel diameter, plunger stopper contact length, needle length and inner diameter) that can be optimized to further mitigate injection resistance and enhance injectability. Transitioning from 29-gauge to 27-gauge needles reduced glide force by 59 % (32 N → 13 N) during administration of 1 mL 20-centipoise viscous fluid (10 s injection), demonstrating enhanced injectability of high-viscosity formulations. Furthermore, a simulated human factors study with a diverse cohort (n = 12) evaluated the usability of the optimized device. A reduction in glide force correlates with an improvement in user perception and usability. Collectively, these combined studies provide practical, patient-centric design strategies to advance PFS injectability, linking technical optimization with real-world usability requirements.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SyringesHumansInjections, SubcutaneousViscosityEquipment DesignDrug PackagingSilicone OilsSelf AdministrationNeedlesAdult

Stichwörter der Autor:innen

Drug-device combination productHuman factorsInjectabilityInjection forcePatient-centric designPrefilled syringe (PFS)

Substanzen

Silicone Oils

Autor:innen und Institutionen

  • Drug Product Development, WuXi Biologics, No. 1951 Huifeng West Rd., 201401 Shanghai City, China.
  • Drug Product Development, WuXi Biologics, No. 1951 Huifeng West Rd., 201401 Shanghai City, China. Electronic address: chen_quanmin@wuxibiologics.com.
  • Drug Product Development, WuXi Biologics, No. 1951 Huifeng West Rd., 201401 Shanghai City, China. Electronic address: jeremy_guo@wuxibiologics.com.

Zitieren

APA

Wang, Y., Li, H., Wu, L., Zhao, Z., Chen, Q., & Guo, J. (2025). Improving prefilled syringe injectability: influences of critical component attributes and human factors. European Journal of Pharmaceutics and Biopharmaceutics, 217, 114901. https://doi.org/10.1016/j.ejpb.2025.114901

Vancouver

Wang Y, Li H, Wu L, Zhao Z, Chen Q, Guo J. Improving prefilled syringe injectability: influences of critical component attributes and human factors. European Journal of Pharmaceutics and Biopharmaceutics. 2025;217:114901. doi:10.1016/j.ejpb.2025.114901

BibTeX
@article{Wang2025,
  author = {Wang, Yunyun and Li, Hui and Wu, Linke and Zhao, Zhixin and Chen, Quanmin and Guo, Jeremy},
  title = {Improving prefilled syringe injectability: influences of critical component attributes and human factors},
  journal = {European Journal of Pharmaceutics and Biopharmaceutics},
  year = {2025},
  volume = {217},
  pages = {114901},
  doi = {10.1016/j.ejpb.2025.114901}
}
Kostenlos starten →