An experimental imaging dose estimation method for the phase-II proton CT scanner
Physica Medica · 2026-12 · 152 · 107223
DOI: 10.1016/j.ejmp.2026.107223 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physica Medica, 2026-12. Verfasst von Lei Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, LMU University Hospital, LMU Medizin, LMU Munich, Munich, 81377, Germany. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China Scholarship Council.
Abstract (Originalsprache)
PURPOSE: Proton computed tomography (pCT) improves range accuracy in proton therapy by directly mapping proton stopping power relative to water (RSP). Imaging dose remains a crucial factor in determining the feasibility of daily image guidance. This study presents an experimental methodology for estimating imaging dose in the phase-II pCT scanner, utilizing phase space data recorded at the front tracker to eliminate phantom-specific corrections. The estimated doses are validated against ionization chamber (IC) measurements. METHODS: Dose measurements were conducted at multiple locations and angles within two phantoms, with data acquisition triggered by either the front trackers or the energy detector. Baseline scans were also performed without phantoms. Monte Carlo (MC) simulations were used to estimate imaging dose in single projections and full scans. Eight front-tracker-triggered baseline datasets were processed for proton track reconstruction and fluence estimation. After assessing inter-run variability, phase space files were averaged to generate an input source for MC simulations. The simulated imaging doses were renormalized to the averaged datasets and quantitatively compared against IC measurements. RESULTS: Analyzed proton track numbers exhibited consistency across datasets, with coefficients of variation below 2.0%. Estimated doses agreed with IC measurements within ±1.8% for the CTDI phantom; head phantom underestimated -4.6% (single projection) and -6.7% (full scan). Uncertainties from multiple measurements remained below 1.9%. CONCLUSION: This study introduces a reliable workflow for imaging dose estimation in the phase-II pCT scanner. The approach demonstrates satisfactory agreement with IC measurements, supporting its feasibility for evaluating imaging dose in image-guided and adaptive proton therapy.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, LMU University Hospital, LMU Medizin, LMU Munich, Munich, 81377, Germany.
- Department of Physics, UC Santa Cruz, Santa Cruz, CA 95064, United States of America.
- Northwestern Medicine Chicago Proton Center, Warrenville, IL 60555, United States of America.
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Garching b. München, 85748, Germany.
- Division of Biomedical Engineering Sciences, Loma Linda University, Loma Linda, CA 92354, United States of America.
- Department of Radiation Oncology, LMU University Hospital, LMU Medizin, LMU Munich, Munich, 81377, Germany; German Cancer Consortium (DKTK), partner site Munich, a partnership between DKFZ and LMU University Hospital, M…
Förderung
- China Scholarship Council
Zitieren
APA
Chen, L., Johnson, R. P., Pankuch, M., Bortfeldt, J., Parodi, K., Schulte, R., Landry, G., & Dedes, G. (2026). An experimental imaging dose estimation method for the phase-II proton CT scanner. Physica Medica, 152, 107223. https://doi.org/10.1016/j.ejmp.2026.107223
Vancouver
Chen L, Johnson RP, Pankuch M, Bortfeldt J, Parodi K, Schulte R, et al. An experimental imaging dose estimation method for the phase-II proton CT scanner. Physica Medica. 2026;152:107223. doi:10.1016/j.ejmp.2026.107223
BibTeX
@article{Chen2026,
author = {Chen, Lei and Johnson, Robert P and Pankuch, Mark and Bortfeldt, Jonathan and Parodi, Katia and Schulte, Reinhard and Landry, Guillaume and Dedes, George},
title = {An experimental imaging dose estimation method for the phase-II proton CT scanner},
journal = {Physica Medica},
year = {2026},
volume = {152},
pages = {107223},
doi = {10.1016/j.ejmp.2026.107223}
}
EUVIMED