EUVIMEDEUVIMED entdecken
Crossref

Patient radiation dose during hospitalization for acute ischemic Stroke: Five years of experience of a single tertiary referral hospital

Sergio Zucca, Federico Fusaro, Alberto Fenu, Antonio Ferrari, Federica Schirru, Marco Erta, Simona Corraine, Giuseppe Fenu, Jessica Moller, Giovanni Cossu, Giovanni Maria Argiolas, Paolo Siotto und 1 weitere

Physica Medica · 2025

DOI: 10.1016/j.ejmp.2025.105016 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physica Medica, 2025. Verfasst von Sergio Zucca und 12 weiteren Autor:innen. Beteiligte Einrichtung: Medical Physics, ARNAS G. Brotzu Cagliari, Italy. Electronic address: sergio.zucca@aob.it. Hauptthemen laut MEDLINE: Radiation Dosage, Ischemic Stroke, Tertiary Care Centers, Hospitalization. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 48 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To assess local radiation dose levels and quantify the contribution of individual X-ray procedures to the cumulative effective dose during hospitalization for acute ischemic stroke (AIS). METHODS: A dosimetric survey was conducted in AIS patients undergoing fluoroscopically guided mechanical thrombectomy (MT). Radiation dose data were collected using a commercial Radiation Dose Monitoring System (RDMS) while clinical data were extracted from the Hospital Information System (HIS) and merged with dose records for comprehensive analysis. Local dose levels were determined for all X-ray procedures, including admission diagnostic CT scans, MT, and follow-up CT before discharge. RESULTS: A total of 670 MT procedures were analyzed. The median Kerma Area Product (KAP) was 115 Gy·cm2 (IQR: 69-189). Median dose-length product (DLP) values for CT scans were: Brain CT at admission, 1091 mGy·cm (IQR: 782-1171); CT angiography, 1077 mGy·cm (IQR: 773-1187); CT perfusion, 2529 mGy·cm (IQR: 2055-2961); and Brain CT at discharge, 844 mGy·cm (IQR: 689-946). The estimated cumulative effective dose for the complete workflow was 22.4 mSv (IQR: 17.1-29.7), with interventional procedures contributing approximately 50 %. CT perfusion accounted for an additional 5 mSv. CONCLUSIONS: This study quantified local radiation dose levels for MT and associated CT imaging in AIS patients treated in a high-volume interventional radiology suite. A cumulative effective dose of 22 mSv is associated with the entire patient workflow, with MT procedures accounting for approximately 50 %. Further research is needed to assess organ dose in complex care pathways, as an estimate of patient-specific radiation risk.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation DosageIschemic StrokeTertiary Care CentersHospitalizationHumansMaleAgedFemaleMiddle AgedTomography, X-Ray ComputedAged, 80 and overThrombectomy

Autor:innen und Institutionen

  • Medical Physics, ARNAS G. Brotzu Cagliari, Italy. Electronic address: sergio.zucca@aob.it.
  • Interventional Radiology, ARNAS G. Brotzu Cagliari, Italy.
  • Neurology, ARNAS G. Brotzu Cagliari, Italy.
  • Radiology, ARNAS G. Brotzu Cagliari, Italy.

Zitieren

APA

Zucca, S., Fusaro, F., Fenu, A., Ferrari, A., Schirru, F., Erta, M., Corraine, S., Fenu, G., Moller, J., Cossu, G., Argiolas, G. M., Siotto, P., & Comelli, S. (2025). Patient radiation dose during hospitalization for acute ischemic Stroke: Five years of experience of a single tertiary referral hospital. Physica Medica. https://doi.org/10.1016/j.ejmp.2025.105016

Vancouver

Zucca S, Fusaro F, Fenu A, Ferrari A, Schirru F, Erta M, et al. Patient radiation dose during hospitalization for acute ischemic Stroke: Five years of experience of a single tertiary referral hospital. Physica Medica. 2025. doi:10.1016/j.ejmp.2025.105016

BibTeX
@article{Zucca2025,
  author = {Zucca, Sergio and Fusaro, Federico and Fenu, Alberto and Ferrari, Antonio and Schirru, Federica and Erta, Marco and Corraine, Simona and Fenu, Giuseppe and Moller, Jessica and Cossu, Giovanni and Argiolas, Giovanni Maria and Siotto, Paolo and Comelli, Simone},
  title = {Patient radiation dose during hospitalization for acute ischemic Stroke: Five years of experience of a single tertiary referral hospital},
  journal = {Physica Medica},
  year = {2025},
  doi = {10.1016/j.ejmp.2025.105016}
}
Kostenlos starten →