Simulation of digital mammographic images using GAMOS: Proof of concept
Physica Medica · 2025
DOI: 10.1016/j.ejmp.2025.104995 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physica Medica, 2025. Verfasst von F R Lozano und 4 weiteren Autor:innen. Beteiligte Einrichtung: Universidad Complutense de Madrid, Madrid, 28040, Spain. Electronic address: frloza03@ucm.es. Hauptthemen laut MEDLINE: Mammography, Computer Simulation, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Ministerio de Ciencia e Innovación.
Abstract (Originalsprache)
PURPOSE: To present a simulation pipeline for digital mammography based on the GAMOS framework, enabling realistic image formation and dose estimation using high-fidelity anatomical phantoms and flexible detector modeling. METHODS: A complete in silico model was implemented using GAMOS and GEANT4, including a Siemens Mammomat Inspiration system geometry, VICTRE voxelized breast phantoms, and two detector models: a direct conversion detector (MCD) and a virtual detector (VD). The simulation incorporated an anti-scatter grid, dose scoring tools, and a GUI for parameter adjustment. Performance metrics were calculated according to IEC 62220-1-2:2007. RESULTS: The simulation yielded realistic mammographic images and accurate dose estimates. The MTF, NNPS, and DQE were calculated for both detector models and compared against published values. Maximum DQE differences were approximately 20%, with comparisons performed at spatial frequencies of 0.5, 2.0 and 5.0 mm-1. The MTF50% was 4.25 mm-1 (VD) and 4.35 mm-1 (MCD). Anatomical noise analysis showed β values between 2.67 and 3.16, consistent with clinical data. Dose validation against AAPM TG-195 showed differences below 1.08%. CONCLUSION: The proposed simulation framework is capable of producing realistic mammographic images and accurate dose calculations using an accessible interface. This tool is suitable for virtual clinical trials and system performance evaluation, and allows further extension to advanced imaging techniques such as contrast-enhanced or phase-contrast mammography. Code: https://github.com/PREDICO-Project/MIMAC.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Universidad Complutense de Madrid, Madrid, 28040, Spain. Electronic address: frloza03@ucm.es.
- Universidad Complutense de Madrid, Madrid, 28040, Spain.
- Hospital Universitario La Paz, Madrid, 28046, Spain.
- Hospital Universitario 12 de Octubre, Madrid, 28041, Spain.
Förderung
- Ministerio de Ciencia e Innovación
Zitieren
APA
Lozano, F. R., Sanchez-Lara, V., Huerga, C., Martinez-Gomez, L. C., & Garcia-Pinto, D. (2025). Simulation of digital mammographic images using GAMOS: Proof of concept. Physica Medica. https://doi.org/10.1016/j.ejmp.2025.104995
Vancouver
Lozano FR, Sanchez-Lara V, Huerga C, Martinez-Gomez LC, Garcia-Pinto D. Simulation of digital mammographic images using GAMOS: Proof of concept. Physica Medica. 2025. doi:10.1016/j.ejmp.2025.104995
BibTeX
@article{Lozano2025,
author = {Lozano, F R and Sanchez-Lara, V and Huerga, C and Martinez-Gomez, Luis C and Garcia-Pinto, D},
title = {Simulation of digital mammographic images using GAMOS: Proof of concept},
journal = {Physica Medica},
year = {2025},
doi = {10.1016/j.ejmp.2025.104995}
}
EUVIMED