Synthetic CT for gamma knife radiosurgery dose calculation: A feasibility study

Fiona Li, Yuanguang Xu, Olga D Lemus, Tony J C Wang, Michael B Sisti, Cheng-Shie Wuu

Physica Medica · 2024

DOI: 10.1016/j.ejmp.2024.104504 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physica Medica, 2024. Verfasst von Fiona Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Columbia University, New York, NY, USA. Electronic address: fenglifiona_li@urmc.rochester.edu. Hauptthemen laut MEDLINE: Radiosurgery, Feasibility Studies, Radiotherapy Dosage, Radiotherapy Planning, Computer-Assisted. Die Arbeit nennt 42 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To determine if MRI-based synthetic CTs (sCT), generated with no predefined pulse sequence, can be used for inhomogeneity correction in routine gamma knife radiosurgery (GKRS) treatment planning dose calculation. METHODS: Two sets of sCTs were generated from T1post and T2 images using cycleGAN. Twenty-eight patients (18 training, 10 validation) were retrospectively selected. The image quality of the generated sCTs was compared with the original CT (oCT) regarding the HU value preservation using histogram comparison, RMSE and MAE, and structural integrity. Dosimetric comparisons were also made among GKRS plans from 3 calculation approaches: TMR10 (oCT), and convolution (oCT and sCT), at four locations: original disease site, bone/tissue interface, air/tissue interface, and mid-brain. RESULTS: The study showed that sCTs and oCTs' HU were similar, with T2-sCT performing better. TMR10 significantly underdosed the target by a mean of 5.4% compared to the convolution algorithm. There was no significant difference in convolution algorithm shot time between the oCT and sCT generated with T2. The highest and lowest dosimetric differences between the two CTs were observed in the bone and air interface, respectively. Dosimetric differences of 3.3% were observed in sCT predicted from MRI with stereotactic frames, which was not included in the training sets. CONCLUSIONS: MRI-based sCT can be utilized for GKRS convolution dose calculation without the unnecessary radiation dose, and sCT without metal artifacts could be generated in framed cases. Larger datasets inclusive of all pulse sequences can improve the training set. Further investigation and validation studies are needed before clinical implementation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiosurgeryFeasibility StudiesRadiotherapy DosageRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedHumansMagnetic Resonance ImagingRadiation DosageRetrospective StudiesRadiometry

Stichwörter der Autor:innen

Convolution algorithmDeep learningGamma Knife RadiosurgeryTMR10

Autor:innen und Institutionen

  • Department of Radiation Oncology, Columbia University, New York, NY, USA. Electronic address: fenglifiona_li@urmc.rochester.edu.
  • Department of Radiation Oncology, Columbia University, New York, NY, USA.
  • Department of Neurological Surgery, Columbia University, New York, NY, USA.

Zitieren

APA

Li, F., Xu, Y., Lemus, O. D., Wang, T. J. C., Sisti, M. B., & Wuu, C. S. (2024). Synthetic CT for gamma knife radiosurgery dose calculation: A feasibility study. Physica Medica. https://doi.org/10.1016/j.ejmp.2024.104504

Vancouver

Li F, Xu Y, Lemus OD, Wang TJC, Sisti MB, Wuu CS. Synthetic CT for gamma knife radiosurgery dose calculation: A feasibility study. Physica Medica. 2024. doi:10.1016/j.ejmp.2024.104504

BibTeX
@article{Li2024,
  author = {Li, Fiona and Xu, Yuanguang and Lemus, Olga D and Wang, Tony J C and Sisti, Michael B and Wuu, Cheng-Shie},
  title = {Synthetic CT for gamma knife radiosurgery dose calculation: A feasibility study},
  journal = {Physica Medica},
  year = {2024},
  doi = {10.1016/j.ejmp.2024.104504}
}
Kostenlos starten →