Sensitivity of automated and manual treatment planning approaches to contouring variation in early-breast cancer treatment
Physica Medica · 2024
DOI: 10.1016/j.ejmp.2024.103402 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physica Medica, 2024. Verfasst von Michele Zeverino und 6 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Breast Neoplasms, Automation, Radiotherapy Dosage. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
PURPOSE: One of the advantages of integrating automated processes in treatment planning is the reduction of manual planning variability. This study aims to assess whether a deep-learning-based auto-planning solution can also reduce the contouring variation-related impact on the planned dose for early-breast cancer treatment. METHODS: Auto- and manual plans were optimized for 20 patients using both auto- and manual OARs, including both lungs, right breast, heart, and left-anterior-descending (LAD) artery. Differences in terms of recalculated dose (ΔDrcM,ΔDrcA) and reoptimized dose (ΔDroM,ΔDroA) for manual (M) and auto (A)-plans, were evaluated on manual structures. The correlation between several geometric similarities and dose differences was also explored (Spearman's test). RESULTS: Auto-contours were found slightly smaller in size than manual contours for right breast and heart and more than twice larger for LAD. Recalculated dose differences were found negligible for both planning approaches except for heart (ΔDrcM=-0.4 Gy, ΔDrcA=-0.3 Gy) and right breast (ΔDrcM=-1.2 Gy, ΔDrcA=-1.3 Gy) maximum dose. Re-optimized dose differences were considered equivalent to recalculated ones for both lungs and LAD, while they were significantly smaller for heart (ΔDroM=-0.2 Gy, ΔDroA=-0.2 Gy) and right breast (ΔDroM =-0.3 Gy, ΔDroA=-0.9 Gy) maximum dose. Twenty-one correlations were found for ΔDrcM,A (M=8,A=13) that reduced to four for ΔDroM,A (M=3,A=1). CONCLUSIONS: The sensitivity of auto-planning to contouring variation was found not relevant when compared to manual planning, regardless of the method used to calculate the dose differences. Nonetheless, the method employed to define the dose differences strongly affected the correlation analysis resulting highly reduced when dose was reoptimized, regardless of the planning approach.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
- Radiation Oncology Department, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
- Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland. Electronic address: raphael.moeckli@chuv.ch.
Zitieren
APA
Zeverino, M., Piccolo, C., Marguet, M., Jeanneret-Sozzi, W., Bourhis, J., Bochud, F., & Moeckli, R. (2024). Sensitivity of automated and manual treatment planning approaches to contouring variation in early-breast cancer treatment. Physica Medica. https://doi.org/10.1016/j.ejmp.2024.103402
Vancouver
Zeverino M, Piccolo C, Marguet M, Jeanneret-Sozzi W, Bourhis J, Bochud F, et al. Sensitivity of automated and manual treatment planning approaches to contouring variation in early-breast cancer treatment. Physica Medica. 2024. doi:10.1016/j.ejmp.2024.103402
BibTeX
@article{Zeverino2024,
author = {Zeverino, Michele and Piccolo, Consiglia and Marguet, Maud and Jeanneret-Sozzi, Wendy and Bourhis, Jean and Bochud, Francois and Moeckli, Raphaël},
title = {Sensitivity of automated and manual treatment planning approaches to contouring variation in early-breast cancer treatment},
journal = {Physica Medica},
year = {2024},
doi = {10.1016/j.ejmp.2024.103402}
}
EUVIMED