Fachartikel in der Zeitschrift Physica Medica, 2023. Verfasst von Xu Li und 11 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Deep Learning. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 41 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Flat-panel X-ray source is an experimental X-ray emitter with target application of static computer tomography (CT), which can save imaging space and time. However, the X-ray cone beams emitted by the densely arranged micro-ray sources are overlapped, causing serious structural overlapping and visual blur in the projection results. Traditional deoverlapping methods can hardly solve this problem well. METHOD: We converted the overlapping cone beam projections to parallel beam projections through a U-like neural network and selected structural similarity (SSIM) loss as the loss function. In this study, we converted three kinds of overlapping cone beam projections of the Shepp-Logan, line-pairs, and abdominal data with two overlapping levels to corresponding parallel beam projections. Training completed, we tested the model using the test set data that was not used at the training phase, and evaluated the difference between the test set conversion results and their corresponding parallel beams through three indicators: mean squared error (MSE), peak signal-to-noise ratio (PSNR) and SSIM. In addition, projections from head phantoms were applied for generalization test. RESULT: In the Shepp-Logan low-overlapping task, we obtained a MSE of 1.624×10-5, a PSNR of 47.892 dB, and a SSIM of 0.998 which are the best results of the six experiments. For the most challenging abdominal task, the MSE, PSNR, and SSIM are 1.563×10-3, 28.0586 dB, and 0.983, respectively. In more generalized data, the model also achieved good results. CONCLUSION: This study proves the feasibility of utilizing the end-to-end U-net for deblurring and deoverlapping in the flat-panel X-ray source domain.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China.
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzho…
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China. Electronic address: smart@smu.edu.cn.
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China. Electronic address: yuanxu@smu.edu.cn.
- Department of Radiology, Nanfang Hospital, Southern Medical University, Guangzhou 510515, China. Electronic address: zealotq@smu.edu.cn.
Zitieren
APA
Li, X., Huang, S., Pan, Z., Qin, P., Wu, W., Qi, M., Ma, J., Kang, S., Chen, J., Zhou, L., Xu, Y., & Qin, G. (2023). Deep learning based de-overlapping correction of projections from a flat-panel micro array X-ray source: Simulation study. Physica Medica. https://doi.org/10.1016/j.ejmp.2023.102607
Vancouver
Li X, Huang S, Pan Z, Qin P, Wu W, Qi M, et al. Deep learning based de-overlapping correction of projections from a flat-panel micro array X-ray source: Simulation study. Physica Medica. 2023. doi:10.1016/j.ejmp.2023.102607
BibTeX
@article{Li2023,
author = {Li, Xu and Huang, Shuang and Pan, Zengxiang and Qin, Peishan and Wu, Wangjiang and Qi, Mengke and Ma, Jianhui and Kang, Song and Chen, Jun and Zhou, Linghong and Xu, Yuan and Qin, Genggeng},
title = {Deep learning based de-overlapping correction of projections from a flat-panel micro array X-ray source: Simulation study},
journal = {Physica Medica},
year = {2023},
doi = {10.1016/j.ejmp.2023.102607}
}
EUVIMED