Effects of incoming particle energy and cluster size on the G-value of hydrated electrons
Physica Medica · 2023
DOI: 10.1016/j.ejmp.2023.102540 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physica Medica, 2023. Verfasst von Alaina Bui und 5 weiteren Autor:innen. Beteiligte Einrichtung: Medical Physics Unit, Department of Oncology, Faculty of Medicine, McGill University, Montréal, Quebec, Canada. Electronic address: giang.bui@mail.mc…. Hauptthemen laut MEDLINE: Electrons, Linear Energy Transfer. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 58 Literaturangaben.
Abstract (Originalsprache)
In hydrated electron (e-aq) dosimetry, absorbed radiation dose to water is measured by monitoring the concentration of radiation-induced e-aq. However, to obtain accurate dose, the radiation chemical yield of e-aq, G(e-aq), is needed for the radiation quality/setup under investigation. The aim of this study was to investigate the time-evolution of the G-values for the main generated reactive species during water radiolysis using GEANT4-DNA. The effects of cluster size and linear energy transfer (LET) on G(e-aq) were examined. Validity of GEANT4-DNA for calculation of G(e-aq) for clinically relevant energies was studied. Three scenarios were investigated with different phantom sizes and incoming electron energies (1 keV to 1 MeV). The time evolution of G(e-aq) was in good agreement with published data and did not change with decreasing phantom size. The time-evolution of the G-values increases with increasing LET for all radiolytic species. The particle tracks formed with high-energy electrons are separated and the resulting reactive species develop independently in time. With decreasing energy, the mean separation distance between reactive species decreases. The particle tracks might not initially overlap but will overlap shortly thereafter due to diffusion of reactive species, increasing the probability of e-aq recombination with other species. This also explains the decrease of G(e-aq) with cluster size and LET. Finally, if all factors are kept constant, as the incoming electron energy increases to clinically relevant energies, G(e-aq) remains similar to its value at 1 MeV, hence GEANT4-DNA can be used for clinically relevant energies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Medical Physics Unit, Department of Oncology, Faculty of Medicine, McGill University, Montréal, Quebec, Canada. Electronic address: giang.bui@mail.mcgill.ca.
- Medical Physics Unit, Department of Oncology, Faculty of Medicine, McGill University, Montréal, Quebec, Canada; Radiation Oncology Department, Jewish General Hospital, Montréal, Quebec, Canada.
- Department of Physics, McGill University, Montréal, Quebec, Canada.
- Medical Physics Unit, Department of Oncology, Faculty of Medicine, McGill University, Montréal, Quebec, Canada; Research Institute of the McGill University Health Centre, Montréal, Quebec, Canada.
- Medical Physics Unit, Department of Oncology, Faculty of Medicine, McGill University, Montréal, Quebec, Canada; Research Institute of the McGill University Health Centre, Montréal, Quebec, Canada; Lady Davis Institute f…
Zitieren
APA
Bui, A., Bekerat, H., Childress, L., Sankey, J., Seuntjens, J., & Enger, S. A. (2023). Effects of incoming particle energy and cluster size on the G-value of hydrated electrons. Physica Medica. https://doi.org/10.1016/j.ejmp.2023.102540
Vancouver
Bui A, Bekerat H, Childress L, Sankey J, Seuntjens J, Enger SA. Effects of incoming particle energy and cluster size on the G-value of hydrated electrons. Physica Medica. 2023. doi:10.1016/j.ejmp.2023.102540
BibTeX
@article{Bui2023,
author = {Bui, Alaina and Bekerat, Hamed and Childress, Lilian and Sankey, Jack and Seuntjens, Jan and Enger, Shirin A},
title = {Effects of incoming particle energy and cluster size on the G-value of hydrated electrons},
journal = {Physica Medica},
year = {2023},
doi = {10.1016/j.ejmp.2023.102540}
}
EUVIMED