EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY-NC-ND 4.0

Comparison of Ambu® AuraGain™ laryngeal mask and air-Q™ intubating laryngeal airway for blind tracheal intubation in adults: A randomized controlled trial

Sameer Sethi, Souvik Maitra, Vikas Saini, Tanvir Samara

Egyptian Journal of Anaesthesia · 2017-04 · 33 (2) · 137-140

DOI: 10.1016/j.egja.2017.03.002 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Egyptian Journal of Anaesthesia, online erschienen am 17.05.2019. Verfasst von Sameer Sethi und 3 weiteren Autor:innen. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BackgroundThis study has been designed to compare the performance of Ambu® AuraGain™ laryngeal mask with the air-Q™ as a conduit for blind tracheal intubation in adult patients.MethodsIn this prospective randomized controlled trial blind endotracheal intubation success rates were compared between Ambu® AuraGain™ and air-Q™ intubating laryngeal airway in 90 adult patients. Patients were randomized in two equal groups: Group Ambu® AuraGain™ (n = 45) and Group air-Q™ (n = 45).ResultsTime to insert the laryngeal airway was similar between Ambu® AuraGain™ and air-Q™ (median [IQR] 13[12–14] s versus 14[12–16] s) and in all cases laryngeal mask insertion was possible in first attempt. Intubation success rate at first attempt was significantly higher in air-Q™ group compared to in Ambu® AuraGain™ group (68.9% versus 35.6%; p = 0.002). Overall blind intubation success rate was significantly higher in air-Q™ group in comparison to Ambu® AuraGain™ (80% versus 53.3%; p = 0.007). Intubation time was significantly higher with Ambu® AuraGain™ (p < 0.0001; median difference 4.0 s, 95% CI 2.7, 5.3 s). Blind intubation was significantly easier in air-Q™ group compared to in Ambu® AuraGain™ (42.2% intubation was graded as easy in air-Q™ instead of 22.2% in Ambu® AuraGain™, p = 0.04). Comparison of fibreoptic bronchoscopic glottis view was similar between the two devices (p = 0.07). Reported complications were infrequent and similar between the two devices.ConclusionWe conclude that air-Q™ laryngeal airway is superior to Ambu® AuraGain™ when used as a conduit for blind endotracheal intubation in adult patients.Trial registrationClinical Trial Registry of India (CTRI/2015/02/005553).

Zitieren

APA

Sethi, S., Maitra, S., Saini, V., & Samara, T. (2017). Comparison of Ambu® AuraGain™ laryngeal mask and air-Q™ intubating laryngeal airway for blind tracheal intubation in adults: A randomized controlled trial. Egyptian Journal of Anaesthesia, 33(2), 137-140. https://doi.org/10.1016/j.egja.2017.03.002

Vancouver

Sethi S, Maitra S, Saini V, Samara T. Comparison of Ambu® AuraGain™ laryngeal mask and air-Q™ intubating laryngeal airway for blind tracheal intubation in adults: A randomized controlled trial. Egyptian Journal of Anaesthesia. 2017;33(2):137-140. doi:10.1016/j.egja.2017.03.002

BibTeX
@article{Sethi2017,
  author = {Sethi, Sameer and Maitra, Souvik and Saini, Vikas and Samara, Tanvir},
  title = {Comparison of Ambu® AuraGain™ laryngeal mask and air-Q™ intubating laryngeal airway for blind tracheal intubation in adults: A randomized controlled trial},
  journal = {Egyptian Journal of Anaesthesia},
  year = {2017},
  volume = {33},
  number = {2},
  pages = {137--140},
  doi = {10.1016/j.egja.2017.03.002}
}
Kostenlos starten →