Comparison of Three-Dimensional and Two-Dimensional Speckle-Tracking Longitudinal Strain with Late Gadolinium Enhancement by Cardiac Magnetic Resonance for Left Ventricular Myocardial Fibrosis in Patients with End-Stage Heart Failure
Journal of the American Society of Echocardiography · 2026
DOI: 10.1016/j.echo.2025.12.010 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of the American Society of Echocardiography, 2026. Verfasst von Mingzhu Qian und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China; Clinical Rese…. Hauptthemen laut MEDLINE: Heart Failure, Echocardiography, Three-Dimensional, Ventricular Dysfunction, Left, Magnetic Resonance Imaging, Cine. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Themen: Herzinsuffizienz
Abstract (Originalsprache)
AIMS: Left ventricular (LV) strain derived by three-dimensional (3D) speckle-tracking echocardiography (STE) has been demonstrated to be correlated with myocardial fibrosis (MF). However, whether 3D-STE parameters provided a similar estimation of LV MF compared with two-dimensional (2D) STE indices and late gadolinium enhancement (LGE) of cardiac magnetic resonance (CMR) imaging against histological MF remains unknown. The aim of this study was to determine whether 3D-STE parameters were similar to 2D-STE indices and LGE CMR in assessing LV MF in patients with end-stage heart failure (HF) against histological MF. METHODS: Speckle-tracking echocardiography and CMR were performed in 109 patients with end-stage HF who underwent heart transplantation. Left ventricular global longitudinal strain (GLS), global circumferential strain (GCS), and global radial strain (GRS) were obtained from 2D-STE and 3D-STE. The degree of MF was assessed using LGE CMR and Masson's staining of the LV myocardial samples. One hundred nine patients were divided into 3 groups based on the tertiles of histologic MF. RESULTS: Myocardial fibrosis was strongly correlated with 3D-GLS (r = 0.70, P .05 for both). The positive and negative predictive values, as well as the area under the curve for identifying severe MF, were comparable among 3D-GLS, 2D-GLS, and LGE. The model with 3D-GLS (R2 = 0.53, P < .001; Akaike information criterion = 413) was similar to that with LGE (R2 = 0.50, P < .001; Akaike information criterion = 418) for reflecting the degree of LV MF. CONCLUSIONS: Three-dimensional GLS can be considered a novel functional parameter that may correlate with the extent of LV MF in patients with end-stage HF, demonstrating accuracy comparable to that of 2D-GLS and LGE CMR in identifying severe MF.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China; Clinical Research Center for Medical Imaging in Hubei Province, Wuhan, China; Hubei…
- Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Qian, M., Dong, N., Zhang, L., Wang, J., Shu, S., Li, Y., Zhang, Y., Zhu, S., Gao, L., Ji, M., Lin, Y., Wu, C., Sun, W., Wang, J., Yang, Y., Lv, Q., Xie, M., & Li, Y. (2026). Comparison of Three-Dimensional and Two-Dimensional Speckle-Tracking Longitudinal Strain with Late Gadolinium Enhancement by Cardiac Magnetic Resonance for Left Ventricular Myocardial Fibrosis in Patients with End-Stage Heart Failure. Journal of the American Society of Echocardiography. https://doi.org/10.1016/j.echo.2025.12.010
Vancouver
Qian M, Dong N, Zhang L, Wang J, Shu S, Li Y, et al. Comparison of Three-Dimensional and Two-Dimensional Speckle-Tracking Longitudinal Strain with Late Gadolinium Enhancement by Cardiac Magnetic Resonance for Left Ventricular Myocardial Fibrosis in Patients with End-Stage Heart Failure. Journal of the American Society of Echocardiography. 2026. doi:10.1016/j.echo.2025.12.010
BibTeX
@article{Qian2026,
author = {Qian, Mingzhu and Dong, Nianguo and Zhang, Li and Wang, Jing and Shu, Shenglei and Li, Yumin and Zhang, Yanting and Zhu, Shuangshuang and Gao, Lang and Ji, Mengmeng and Lin, Yixia and Wu, Chun and Sun, Wei and Wang, Jing and Yang, Yali and Lv, Qing and Xie, Mingxing and Li, Yuman},
title = {Comparison of Three-Dimensional and Two-Dimensional Speckle-Tracking Longitudinal Strain with Late Gadolinium Enhancement by Cardiac Magnetic Resonance for Left Ventricular Myocardial Fibrosis in Patients with End-Stage Heart Failure},
journal = {Journal of the American Society of Echocardiography},
year = {2026},
doi = {10.1016/j.echo.2025.12.010}
}
EUVIMED