EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

Artificial Intelligence–Assisted Left Ventricular Diastolic Function Assessment and Grading: Multiview Versus Single View

Xu Chen, Feifei Yang, Peifang Zhang, Xixiang Lin, Wenjun Wang, Haitao Pu, Xiaotian Chen, Yixin Chen, Liheng Yu, Yujiao Deng, Bohan Liu, Yongyi Bai und 2 weitere

Journal of the American Society of Echocardiography · 2023-10 · 36 (10) · 1064-1078

DOI: 10.1016/j.echo.2023.07.001 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of the American Society of Echocardiography, 2023-10. Verfasst von Xu Chen und 13 weiteren Autor:innen. Beteiligte Einrichtung: Medical Big Data Research Center, Chinese PLA General Hospital, Beijing, China; Department of Cardiology, The Second Medical Center of Chinese PLA Ge…. Hauptthemen laut MEDLINE: Artificial Intelligence, Ventricular Dysfunction, Left, Ventricular Function, Left, Heart Ventricles. Die Arbeit wurde bisher 37-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Ministry of Industry and Information Technology of the People's Republic of China, National Natural Science Foundation of China, Ministry of Science and Technology of the People's Republic of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Clinical assessment and grading of left ventricular diastolic function (LVDF) requires quantification of multiple echocardiographic parameters interpreted according to established guidelines, which depends on experienced clinicians and is time consuming. The aim of this study was to develop an artificial intelligence (AI)-assisted system to facilitate the clinical assessment of LVDF. METHODS: In total, 1,304 studies (33,404 images) were used to develop a view classification model to select six specific views required for LVDF assessment. A total of 2,238 studies (16,794 two-dimensional [2D] images and 2,198 Doppler images) to develop 2D and Doppler segmentation models, respectively, to quantify key metrics of diastolic function. We used 2,150 studies with definite LVDF labels determined by two experts to train single-view classification models by AI interpretation of strain metrics or video. The accuracy and efficiency of these models were tested in an external data set of 388 prospective studies. RESULTS: The view classification model identified views required for LVDF assessment with good sensitivity (>0.9), and view segmentation models successfully outlined key regions of these views with intersection over union > 0.8 in the internal validation data set. In the external test data set of 388 cases, AI quantification of 2D and Doppler images showed narrow limits of agreement compared with the two experts (e.g., left ventricular ejection fraction, -12.02% to 9.17%; E/e' ratio, -3.04 to 2.67). These metrics were used to detect LV diastolic dysfunction (DD) and grade DD with accuracy of 0.9 and 0.92, respectively. Concerning the single-view method, the overall accuracy of DD detection was 0.83 and 0.75 by strain-based and video-based models, and the accuracy of DD grading was 0.85 and 0.8, respectively. These models could achieve diagnosis and grading of LVDD in a few seconds, greatly saving time and labor. CONCLUSION: AI models successfully achieved LVDF assessment and grading that compared favorably with human experts reading according to guideline-based algorithms. Moreover, when Doppler variables were missing, AI models could provide assessment by interpreting 2D strain metrics or videos from a single view. These models have the potential to save labor and cost and to facilitate work flow of clinical LVDF assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Artificial IntelligenceVentricular Dysfunction, LeftVentricular Function, LeftHeart VentriclesImage Interpretation, Computer-AssistedEchocardiography, DopplerEchocardiographyHumansDiastoleReproducibility of ResultsFemaleMaleStroke VolumeSensitivity and Specificity

Stichwörter der Autor:innen

Deep learningEchocardiographyLeft ventricular diastolic function

Autor:innen und Institutionen

  • Medical Big Data Research Center, Chinese PLA General Hospital, Beijing, China; Department of Cardiology, The Second Medical Center of Chinese PLA General Hospital, Beijing, China.
  • Medical Big Data Research Center, Chinese PLA General Hospital, Beijing, China; Department of Cardiology, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, China.
  • BioMind Technology, Zhongguancun Medical Engineering Center, Beijing, China.
  • Medical Big Data Research Center, Chinese PLA General Hospital, Beijing, China.
  • Department of Ultrasound Diagnosis, The First Medical Center of Chinese PLA General Hospital, Beijing, China.
  • Department of Cardiology, The Second Medical Center of Chinese PLA General Hospital, Beijing, China.

Förderung

  • Ministry of Industry and Information Technology of the People's Republic of China
  • National Natural Science Foundation of China
  • Ministry of Science and Technology of the People's Republic of China

Zitieren

APA

Chen, X., Yang, F., Zhang, P., Lin, X., Wang, W., Pu, H., Chen, X., Chen, Y., Yu, L., Deng, Y., Liu, B., Bai, Y., Burkhoff, D., & He, K. (2023). Artificial Intelligence–Assisted Left Ventricular Diastolic Function Assessment and Grading: Multiview Versus Single View. Journal of the American Society of Echocardiography, 36(10), 1064-1078. https://doi.org/10.1016/j.echo.2023.07.001

Vancouver

Chen X, Yang F, Zhang P, Lin X, Wang W, Pu H, et al. Artificial Intelligence–Assisted Left Ventricular Diastolic Function Assessment and Grading: Multiview Versus Single View. Journal of the American Society of Echocardiography. 2023;36(10):1064-1078. doi:10.1016/j.echo.2023.07.001

BibTeX
@article{Chen2023,
  author = {Chen, Xu and Yang, Feifei and Zhang, Peifang and Lin, Xixiang and Wang, Wenjun and Pu, Haitao and Chen, Xiaotian and Chen, Yixin and Yu, Liheng and Deng, Yujiao and Liu, Bohan and Bai, Yongyi and Burkhoff, Daniel and He, Kunlun},
  title = {Artificial Intelligence–Assisted Left Ventricular Diastolic Function Assessment and Grading: Multiview Versus Single View},
  journal = {Journal of the American Society of Echocardiography},
  year = {2023},
  volume = {36},
  number = {10},
  pages = {1064--1078},
  doi = {10.1016/j.echo.2023.07.001}
}