Fully Automated Artificial Intelligence Assessment of Aortic Stenosis by Echocardiography
Journal of the American Society of Echocardiography · 2023-07 · 36 (7) · 769-777
DOI: 10.1016/j.echo.2023.03.008 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the American Society of Echocardiography, 2023-07. Verfasst von Hema Krishna und 15 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, University of Illinois at Chicago, Chicago, Illinois; Jesse Brown VA Medical Center, Chicago, Illinois. Hauptthemen laut MEDLINE: Artificial Intelligence, Aortic Valve Stenosis. Die Arbeit wurde bisher 101-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BACKGROUND: Aortic stenosis (AS) is a common form of valvular heart disease, present in over 12% of the population age 75 years and above. Transthoracic echocardiography (TTE) is the first line of imaging in the adjudication of AS severity but is time-consuming and requires expert sonographic and interpretation capabilities to yield accurate results. Artificial intelligence (AI) technology has emerged as a useful tool to address these limitations but has not yet been applied in a fully hands-off manner to evaluate AS. Here, we correlate artificial neural network measurements of key hemodynamic AS parameters to experienced human reader assessment. METHODS: Two-dimensional and Doppler echocardiographic images from patients with normal aortic valves and all degrees of AS were analyzed by an artificial neural network (Us2.ai) with no human input to measure key variables in AS assessment. Trained echocardiographers blinded to AI data performed manual measurements of these variables, and correlation analyses were performed. RESULTS: Our cohort included 256 patients with an average age of 67.6 ± 9.5 years. Across all AS severities, AI closely matched human measurement of aortic valve peak velocity (r = 0.97, P < .001), mean pressure gradient (r = 0.94, P < .001), aortic valve area by continuity equation (r = 0.88, P < .001), stroke volume index (r = 0.79, P < .001), left ventricular outflow tract velocity-time integral (r = 0.89, P < .001), aortic valve velocity-time integral (r = 0.96, P < .001), and left ventricular outflow tract diameter (r = 0.76, P < .001). CONCLUSIONS: Artificial neural networks have the capacity to closely mimic human measurement of all relevant parameters in the adjudication of AS severity. Application of this AI technology may minimize interscan variability, improve interpretation and diagnosis of AS, and allow for precise and reproducible identification and management of patients with AS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiology, University of Illinois at Chicago, Chicago, Illinois; Jesse Brown VA Medical Center, Chicago, Illinois.
- Department of Medicine, University of Illinois at Chicago, Chicago, Illinois.
- Bluhm Cardiovascular Institute, Northwestern University, Chicago, Illinois.
- National Heart Centre Singapore, Singapore; Department of Dermatology, Amsterdam UMC, Amsterdam, Netherlands.
- Us2.ai, Singapore.
- National Heart Centre Singapore, Singapore; Duke-NUS Medical School, Singapore.
Zitieren
APA
Krishna, H., Desai, K., Slostad, B., Bhayani, S., Arnold, J. H., Ouwerkerk, W., Hummel, Y., Lam, C. S. P., Ezekowitz, J., Frost, M., Jiang, Z., Equilbec, C., Twing, A., Pellikka, P. A., Frazin, L., & Kansal, M. (2023). Fully Automated Artificial Intelligence Assessment of Aortic Stenosis by Echocardiography. Journal of the American Society of Echocardiography, 36(7), 769-777. https://doi.org/10.1016/j.echo.2023.03.008
Vancouver
Krishna H, Desai K, Slostad B, Bhayani S, Arnold JH, Ouwerkerk W, et al. Fully Automated Artificial Intelligence Assessment of Aortic Stenosis by Echocardiography. Journal of the American Society of Echocardiography. 2023;36(7):769-777. doi:10.1016/j.echo.2023.03.008
BibTeX
@article{Krishna2023,
author = {Krishna, Hema and Desai, Kevin and Slostad, Brody and Bhayani, Siddharth and Arnold, Joshua H and Ouwerkerk, Wouter and Hummel, Yoran and Lam, Carolyn S P and Ezekowitz, Justin and Frost, Matthew and Jiang, Zhubo and Equilbec, Cyril and Twing, Aamir and Pellikka, Patricia A and Frazin, Leon and Kansal, Mayank},
title = {Fully Automated Artificial Intelligence Assessment of Aortic Stenosis by Echocardiography},
journal = {Journal of the American Society of Echocardiography},
year = {2023},
volume = {36},
number = {7},
pages = {769--777},
doi = {10.1016/j.echo.2023.03.008}
}
EUVIMED