Performance of the NightWatch seizure detection device on the leg compared to the standard arm placement: A pilot study
Epilepsy & Behavior Reports · 2026-12 · 36 · 100903
DOI: 10.1016/j.ebr.2026.100903 ↗Kurz gefasst
Fachartikel in der Zeitschrift Epilepsy & Behavior Reports, 2026-12. Verfasst von Megan Krom und 6 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Netherlands Organisation for Health Research and Development.
Abstract (Originalsprache)
Nighttime monitoring is crucial for individuals with epilepsy, both to reduce the risk of injuries and to help prevent sudden unexpected death in epilepsy. NightWatch, a seizure detection device that can detect nocturnal seizures by using heart rate (HR) and movement parameters, has been shown to be effective when worn on the upper arm. This study piloted whether wearing NightWatch on the lower leg provides comparable seizure detection sensitivity. In this prospective pilot study, NightWatch users wore a second device on the lower leg for four weeks. The positive percent agreement (PPA) was determined for the leg-worn NightWatch compared to the arm module. Differences in signal quality and time spent in rest state (sensor in horizontal position) were evaluated both per participant and across the population. Ten participants (mean age: 12.5 years, range = 5–25) were included in the study. In total, 245 nights were analyzed. PPA ranged from 11.1% to 100%, yielding an overall mean PPA of 76.8% and median of 100%. The quality of HR signal for the leg module was comparable to the arm module ( p = 0.1602). The leg module showed variability across patients and, overall, registered the rest state significantly less often than the arm module ( p = 0.0059). This pilot study demonstrated that NightWatch performance on the leg varies across participants, with comparable results to arm use in some participants but reduced accuracy in others. This study has been registered in the Overview of Medical Research in the Netherlands (OMON) (NL-OMON57506).
Förderung
- Netherlands Organisation for Health Research and Development
Zitieren
APA
Krom, M., Lemmen, E. M., Evers, S. M., Lazeron, R. H., Majoie, M. H., Thijs, R. D., & Dijk, J. P. V. (2026). Performance of the NightWatch seizure detection device on the leg compared to the standard arm placement: A pilot study. Epilepsy & Behavior Reports, 36, 100903. https://doi.org/10.1016/j.ebr.2026.100903
Vancouver
Krom M, Lemmen EM, Evers SM, Lazeron RH, Majoie MH, Thijs RD, et al. Performance of the NightWatch seizure detection device on the leg compared to the standard arm placement: A pilot study. Epilepsy & Behavior Reports. 2026;36:100903. doi:10.1016/j.ebr.2026.100903
BibTeX
@article{Krom2026,
author = {Krom, Megan and Lemmen, Eefke M. and Evers, Silvia M.A.A. and Lazeron, Richard H.C. and Majoie, Marian H.J.M. and Thijs, Roland D. and Dijk, Johannes P. van},
title = {Performance of the NightWatch seizure detection device on the leg compared to the standard arm placement: A pilot study},
journal = {Epilepsy & Behavior Reports},
year = {2026},
volume = {36},
pages = {100903},
doi = {10.1016/j.ebr.2026.100903}
}
EUVIMED