A practical alternative to live cell-based assay for AQP4 and MOG antibody detection
eBioMedicine · 2026-07 · 129 · 106338
DOI: 10.1016/j.ebiom.2026.106338 ↗Kurz gefasst
Fachartikel in der Zeitschrift eBioMedicine, 2026-07. Verfasst von Qi Wang und 16 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Xuanwu Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Aquaporin 4, Myelin-Oligodendrocyte Glycoprotein, Autoantibodies, Myelin Oligodendrocyte Glycoprotein Antibody-Associated Disease. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Capital Medical University, National Science Fund for Distinguished Young Scholars, National Key Research and Development Program of China.
Abstract (Originalsprache)
BACKGROUND: Live cell-based assay (LCBA) is the gold standard for sensitive detection of aquaporin-4 (AQP4) and myelin oligodendrocyte glycoprotein (MOG) autoantibodies in neuromyelitis optica spectrum disorder (NMOSD) and MOG antibody-associated disorder (MOGAD). However, LCBA is less practical, standardisable and cost-effective than fixed cell-based assay (FCBA). METHODS: We developed a high-performance untransfected vector cells lysate, named AbFine, to process patients' sera to pre-bind and deplete interferents before FCBA, and examined its rationality. We then conducted a multicentre, double-blind, prospective discovery study to compare the diagnostic accuracy of conventional FCBA, FCBA-AbFine, and LCBA in detecting AQP4-IgG and MOG-IgG. A retrospective validation cohort was used to assess generalisability. Participants included patients with NMOSD, MOGAD, and seronegative inflammatory demyelination syndromes, and controls with other neurological disorders. FINDINGS: 818 participants were recruited, including 410 in the discovery and 408 in the validation cohorts with good consistency. Among 205 patients with NMOSD, AQP4-IgG was detected in 165, 185, and 178 by FCBA, FCBA-AbFine, and LCBA, yielding sensitivity of 80.5% (95% CI, 74.4-85.7), 90.2% (95% CI, 85.3-93.9), and 86.8% (95% CI, 81.4-91.1), respectively. Among 171 patients with MOGAD, MOG-IgG was found in 134, 155, and 158 by FCBA, FCBA-AbFine, and LCBA, with sensitivity of 78.4% (95% CI, 71.4-84.3), 90.6% (95% CI, 85.3-94.6), and 92.4% (95% CI, 87.4-95.9), respectively. All assays achieved specificity greater than 99.5%. The area under the curve for FCBA-AbFine was higher than that for FCBA for both AQP4-IgG (0.950 vs. 0.902; p 0.05 for both). INTERPRETATION: AbFine enables the use of FCBA as an alternative to LCBA in AQP4-IgG and MOG-IgG detection with operationally practical and cost-efficient characteristics and could be extended to other fixed cellular assays. FUNDING: Beijing Precigen Biopharma Co., Ltd., Beijing, China.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Neurology, Xuanwu Hospital, Capital Medical University, Beijing, China.
- Beijing Precigen Biopharma Co., Ltd., Beijing, China.
- Department of Neurology, The First Affiliated Hospital of Anhui Medical University, Hefei, China.
- Department of Neurology, Zhengzhou University People's Hospital, Zhengzhou, China.
- Department of Neurology, The First Hospital of Shanxi Medical University, Taiyuan, China.
- Department of Neurology, Xuanwu Hospital, Capital Medical University, Beijing, China; Beijing Municipal Geriatric Medical Research Center, Beijing, China; Key Laboratory for Neurodegenerative Diseases of Ministry of Edu…
Förderung
- Capital Medical University
- National Science Fund for Distinguished Young Scholars
- National Key Research and Development Program of China
- Beijing Natural Science Foundation
- Key Technologies Research and Development Program
Zitieren
APA
Wang, Q., Chen, F., Tang, Y., Zhang, J., Sun, Z., Meng, H., Wang, Z., Wang, Y., Tao, S., Lin, M., Zhao, Y., Huang, Y., Guo, J., Tian, Y., Zhang, J., Hao, J., & Liu, L. (2026). A practical alternative to live cell-based assay for AQP4 and MOG antibody detection. eBioMedicine, 129, 106338. https://doi.org/10.1016/j.ebiom.2026.106338
Vancouver
Wang Q, Chen F, Tang Y, Zhang J, Sun Z, Meng H, et al. A practical alternative to live cell-based assay for AQP4 and MOG antibody detection. eBioMedicine. 2026;129:106338. doi:10.1016/j.ebiom.2026.106338
BibTeX
@article{Wang2026,
author = {Wang, Qi and Chen, Feng and Tang, Yuqi and Zhang, Juanjuan and Sun, Zhengyu and Meng, Huaxing and Wang, Zhongzheng and Wang, Yingtao and Tao, Shaoxin and Lin, Ming and Zhao, Yinan and Huang, Yue and Guo, Junhong and Tian, Yanghua and Zhang, Jiewen and Hao, Junwei and Liu, Liang},
title = {A practical alternative to live cell-based assay for AQP4 and MOG antibody detection},
journal = {eBioMedicine},
year = {2026},
volume = {129},
pages = {106338},
doi = {10.1016/j.ebiom.2026.106338}
}
EUVIMED