EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Arthroscopic Acromioclavicular Joint Stabilization Using Autologous Biceps for Horizontal Neutralization (AutoBAHN) Technique

Markus Scheibel, Tobias Gruber, Irina Todiraş, Philipp Vetter

Arthroscopy Techniques · 2025-12 · 14 (12)

DOI: 10.1016/j.eats.2025.103945 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Arthroscopy Techniques, online erschienen am 24.10.2025. Verfasst von Markus Scheibel und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The surgical treatment of chronic acromioclavicular joint (ACJ) instability is most commonly performed using tendon grafts combined with synthetic stabilization. However, autografts can be associated with donor site morbidity, while allografts often have inferior tissue quality and a higher risk of graft failure. We present a technique of arthroscopically assisted ACJ stabilization using an autologous, rerouted long head of the biceps (LHB) tendon transfer, augmented with a suture button pulley construct for the treatment of symptomatic bidirectional ACJ instability. The LHB tendon is tenodesed to the humerus near the musculotendinous junction and tenotomized just proximal to the fixation point. The proximal attachment of the LHB tendon is preserved. The distal free end of the LHB tendon is rerouted transarticularly and passed anterior to the glenoid, proximally through the lateral end of the clavicle. Intraosseous fixation is achieved using an interference screw. The distal LHB tendon portion spans the superior aspect of the ACJ, providing horizontal stabilization. The autologous biceps acromioclavicular and horizontal neutralization technique offers a local, robust, and cost‐effective graft option that avoids potential donor site morbidity, preserves the anatomic origin of the LHB tendon, and provides sufficient length for both vertical and horizontal ACJ stabilization. Technique Video video See video under supplementary data.

Autor:innen und Institutionen

  • Department of Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland.
  • Department of Shoulder and Elbow Surgery, Center for Musculoskeletal Surgery, Charité-Universitaetsmedizin Berlin, Berlin, Germany.
  • Department of Orthopaedic and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Zitieren

APA

Scheibel, M., Gruber, T., Todiraş, I., & Vetter, P. (2025). Arthroscopic Acromioclavicular Joint Stabilization Using Autologous Biceps for Horizontal Neutralization (AutoBAHN) Technique. Arthroscopy Techniques, 14(12). https://doi.org/10.1016/j.eats.2025.103945

Vancouver

Scheibel M, Gruber T, Todiraş I, Vetter P. Arthroscopic Acromioclavicular Joint Stabilization Using Autologous Biceps for Horizontal Neutralization (AutoBAHN) Technique. Arthroscopy Techniques. 2025;14(12). doi:10.1016/j.eats.2025.103945

BibTeX
@article{Scheibel2025,
  author = {Scheibel, Markus and Gruber, Tobias and Todiraş, Irina and Vetter, Philipp},
  title = {Arthroscopic Acromioclavicular Joint Stabilization Using Autologous Biceps for Horizontal Neutralization (AutoBAHN) Technique},
  journal = {Arthroscopy Techniques},
  year = {2025},
  volume = {14},
  number = {12},
  doi = {10.1016/j.eats.2025.103945}
}
Kostenlos starten →