Arthroscopic Reduction and Transosseous Fixation of the Elbow Coronoid Process Fracture Using High‐Strength Suture
Arthroscopy Techniques · 2025-04 · 14 (4)
DOI: 10.1016/j.eats.2024.103341 ↗Kurz gefasst
Fachartikel in der Zeitschrift Arthroscopy Techniques, online erschienen am 27.01.2025. Verfasst von Wenbo Yang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 7 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
A coronoid process fracture of the elbow can affect the stability of the elbow joint. Surgery is typically required when conservative treatment fails to achieve reduction when there is soft tissue incarceration, or in cases of elbow dislocation. Traditional open surgery has potential issues, including a high complication rate, significant surgical difficulty, and poor cost‐effectiveness, which necessitate further improvement. Here, we report a technique for internal fixation of coronoid process fracture. This technique uses an anterior cruciate ligament guide and arthroscopy, employing high‐strength sutures instead of the traditional internal fixation plates and tying procedures for fracture fragment fixation, which achieves minimally invasive, cost‐effective, and safe outcomes. Surgeons can apply this technique flexibly to manage various types of coronoid process fractures, demonstrating significant clinical value for broader application. Technique Video video See video under supplementary data.
Autor:innen und Institutionen
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Yang, W., Peng, Y., Wang, H., Wu, F., He, L., Meng, C., & Huang, W. (2025). Arthroscopic Reduction and Transosseous Fixation of the Elbow Coronoid Process Fracture Using High‐Strength Suture. Arthroscopy Techniques, 14(4). https://doi.org/10.1016/j.eats.2024.103341
Vancouver
Yang W, Peng Y, Wang H, Wu F, He L, Meng C, et al. Arthroscopic Reduction and Transosseous Fixation of the Elbow Coronoid Process Fracture Using High‐Strength Suture. Arthroscopy Techniques. 2025;14(4). doi:10.1016/j.eats.2024.103341
BibTeX
@article{Yang2025,
author = {Yang, Wenbo and Peng, Yizhong and Wang, Hong and Wu, Fashuai and He, Luyi and Meng, Chunqing and Huang, Wei},
title = {Arthroscopic Reduction and Transosseous Fixation of the Elbow Coronoid Process Fracture Using High‐Strength Suture},
journal = {Arthroscopy Techniques},
year = {2025},
volume = {14},
number = {4},
doi = {10.1016/j.eats.2024.103341}
}
EUVIMED