Arthroscopic Modified Double‐Pulley Suture‐Bridge Repair of Medium‐Sized Supraspinatus Tendon Tears
Arthroscopy Techniques · 2024-06 · 13 (6)
DOI: 10.1016/j.eats.2024.102975 ↗Kurz gefasst
Fachartikel in der Zeitschrift Arthroscopy Techniques, online erschienen am 14.03.2024. Verfasst von Peiguan Huang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Joint Surgery, The Second Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang, China. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
At present, the repair patterns for medium‐sized supraspinatus tendon tears are double‐ and single‐row repairs. However, the limitations of double‐row repair include excessive anchor implantation and incremental surgical cost and time, whereas a deficient tendon‐bone contact area exists with single‐row repair. The modified double‐pulley suture‐bridge repair presented in this study is an arthroscopic technique using 3 double‐loaded suture anchors combined with a double‐pulley technique to form a hybrid repair pattern with a double row as the mainstay and a single row as the supplement. In the treatment of medium‐sized tendon tears, the modified double‐pulley suture‐bridge repair can not only maximize the tendon‐bone contact area but also lower the surgical cost and shorten the operative time. The surgical technique is described, including pearls and pitfalls, as well as advantages and disadvantages. Technique Video video See video under supplementary data.
Autor:innen und Institutionen
- Department of Joint Surgery, The Second Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang, China.
Zitieren
APA
Huang, P., Wang, X., He, C., & Peng, B. (2024). Arthroscopic Modified Double‐Pulley Suture‐Bridge Repair of Medium‐Sized Supraspinatus Tendon Tears. Arthroscopy Techniques, 13(6). https://doi.org/10.1016/j.eats.2024.102975
Vancouver
Huang P, Wang X, He C, Peng B. Arthroscopic Modified Double‐Pulley Suture‐Bridge Repair of Medium‐Sized Supraspinatus Tendon Tears. Arthroscopy Techniques. 2024;13(6). doi:10.1016/j.eats.2024.102975
BibTeX
@article{Huang2024,
author = {Huang, Peiguan and Wang, Xiaoxu and He, Chunrong and Peng, Bin},
title = {Arthroscopic Modified Double‐Pulley Suture‐Bridge Repair of Medium‐Sized Supraspinatus Tendon Tears},
journal = {Arthroscopy Techniques},
year = {2024},
volume = {13},
number = {6},
doi = {10.1016/j.eats.2024.102975}
}
EUVIMED