EUVIMEDEUVIMED entdecken
Crossref

Attention-guided fusion of 1D and 2D CNNs for robust ECG-based biometric recognition

Islameddine Arioua, Amir Benzaoui, Abdelhafid Zeroual, Lotfi Houam

Digital Signal Processing · 2026-09 · 180 · 106252

DOI: 10.1016/j.dsp.2026.106252 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Digital Signal Processing, 2026-09. Verfasst von Islameddine Arioua und 3 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrocardiogram (ECG)-based biometric recognition has emerged as a promising solution for secure authentication and liveness detection. However, most existing methods rely on unimodal deep learning architectures that independently process either one-dimensional (1D) temporal signals or two-dimensional (2D) time-frequency representations, limiting robustness and generalization. To address this issue, this paper proposes a hybrid framework integrating 1D and 2D convolutional neural networks (CNNs) within a unified end-to-end architecture. The 1D branch extracts temporal and morphological features from raw ECG signals, while the 2D branch captures discriminative spectral information from time-frequency representations. An attention-guided fusion mechanism dynamically weights both modalities according to input characteristics, overcoming the limitations of conventional static fusion strategies. The framework was evaluated on three benchmark datasets (ECG-ID, MIT-BIH, and PTB), including healthy subjects and patients with cardiac pathologies, achieving identification accuracies of 99.56%, 100.00%, and 99.89%, respectively. To assess long-term biometric permanence, experiments were also conducted on the multi-session Heartprint dataset spanning ten years. The proposed approach achieved same-session accuracies of 98.54% (S1), 99.09% (S2), 94.93% (S3R), and 96.08% (S3L), while cross-session evaluations reached 56.33% (S1-S2) and 53.27% (S2-S3R), demonstrating the ability to capture stable biometric signatures over time. The optimal configuration combines InceptionTime for 1D processing, ResNet-34 for 2D analysis, and attention-based fusion. Ablation studies confirm that the proposed attention mechanism consistently outperforms conventional fusion approaches. Overall, the proposed framework provides a robust, scalable, and high-performance solution for ECG biometric recognition.

Zitieren

APA

Arioua, I., Benzaoui, A., Zeroual, A., & Houam, L. (2026). Attention-guided fusion of 1D and 2D CNNs for robust ECG-based biometric recognition. Digital Signal Processing, 180, 106252. https://doi.org/10.1016/j.dsp.2026.106252

Vancouver

Arioua I, Benzaoui A, Zeroual A, Houam L. Attention-guided fusion of 1D and 2D CNNs for robust ECG-based biometric recognition. Digital Signal Processing. 2026;180:106252. doi:10.1016/j.dsp.2026.106252

BibTeX
@article{Arioua2026,
  author = {Arioua, Islameddine and Benzaoui, Amir and Zeroual, Abdelhafid and Houam, Lotfi},
  title = {Attention-guided fusion of 1D and 2D CNNs for robust ECG-based biometric recognition},
  journal = {Digital Signal Processing},
  year = {2026},
  volume = {180},
  pages = {106252},
  doi = {10.1016/j.dsp.2026.106252}
}
Kostenlos starten →