EUVIMEDEUVIMED entdecken
Multizentrische StudieVergleichsstudieOpen Access · CC BY 4.0

Evaluation of the diagnostic accuracy of two esophageal biopsy sites compared to three in histological follow-up of eosinophilic esophagitis – A multicentric study

Francesco Calabrese, Andrea Pasta, Manuele Furnari, Giorgia Bodini, Federica Grillo, Luca Mastracci, Andrea Sorge, Marina Coletta, Roberto Penagini, Maurizio Vecchi, Beatrice Marinoni, Giovanni Aldinio und 7 weitere

Digestive and Liver Disease · 2026

DOI: 10.1016/j.dld.2026.01.219 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Digestive and Liver Disease, 2026. Verfasst von Francesco Calabrese und 18 weiteren Autor:innen. Beteiligte Einrichtung: Gastroenterology Unit, Department of Internal Medicine, University of Genoa, Genoa, Italy; IRCCS Policlinico San Martino, Genoa, Italy. Electronic ad…. Hauptthemen laut MEDLINE: Eosinophilic Esophagitis, Esophagus. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION AND AIM: Guidelines recommend sampling 2-3 esophageal locations (4-6 biopsies) during EoE follow-up, but the optimal scheme is uncertain. We assessed whether two biopsies (distal, proximal) reliably classify activity versus three sites (distal, middle, proximal). METHODS: Retrospective analysis of EoE follow-up endoscopies (2020-2024, tertiary centers) with three-site histology. Active disease was defined as ≥15 eos/0.3 mm² in ≥1 site; sub-analyses used ≥6 and ≥1 eos/0.3 mm². We compared active/inactive classification for two-site (distal+proximal) versus three-site sampling. RESULTS: Among 634 histologic evaluations, 306 three-site sets and 293 two-site sets were positive at ≥15 eos/0.3 mm²; all 328 three-site negatives remained negative with two sites. Thus, omitting the middle site would miss 2.0 % of active disease. Two-site performance: accuracy 98.0 %, sensitivity 96 %, specificity 100 %, PPV 100 %, NPV 96 %, AUC 0.98 (95 % CI, 0.97-0.99), Cohen's κ 0.98. At ≥6 eos/0.3 mm², sensitivity 97 %, accuracy 98.6 %, AUC 0.98 (95 % CI, 0.98-0.99). At ≥1 eos/0.3 mm², sensitivity 99 %, AUC 0.99 (95 % CI, 0.98-0.99). CONCLUSIONS: In EoE follow-up, two-site (distal+proximal) biopsies provide classification nearly equivalent to three-site sampling, with only a 2 % miss rate for active disease when the middle site is omitted. This approach may reduce procedure time, patient discomfort, and costs while maintaining excellent diagnostic performance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Eosinophilic EsophagitisEsophagusHumansBiopsyRetrospective StudiesFemaleMaleSensitivity and SpecificityAdultMiddle AgedEsophagoscopyFollow-Up StudiesYoung Adult

Stichwörter der Autor:innen

DiagnosisEndoscopyEosinophilsEsophagusImmune-mediated

Autor:innen und Institutionen

  • Gastroenterology Unit, Department of Internal Medicine, University of Genoa, Genoa, Italy; IRCCS Policlinico San Martino, Genoa, Italy. Electronic address: francesco.calabrese@aomliguria.it.
  • Gastroenterology Unit, Department of Internal Medicine, University of Genoa, Genoa, Italy; IRCCS Policlinico San Martino, Genoa, Italy.
  • IRCCS Policlinico San Martino, Genoa, Italy; Department of Surgical Sciences and Integrated Diagnostics, Pathological Anatomy Unit, University of Genoa, Genoa, Italy.
  • Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
  • Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
  • Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy; Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.

Zitieren

APA

Calabrese, F., Pasta, A., Furnari, M., Bodini, G., Grillo, F., Mastracci, L., Sorge, A., Coletta, M., Penagini, R., Vecchi, M., Marinoni, B., Aldinio, G., Pessarelli, T., Visaggi, P., De Bortoli, N., Maniero, D., Giannini, E. G., Savarino, E. V., & Marabotto, E. (2026). Evaluation of the diagnostic accuracy of two esophageal biopsy sites compared to three in histological follow-up of eosinophilic esophagitis – A multicentric study. Digestive and Liver Disease. https://doi.org/10.1016/j.dld.2026.01.219

Vancouver

Calabrese F, Pasta A, Furnari M, Bodini G, Grillo F, Mastracci L, et al. Evaluation of the diagnostic accuracy of two esophageal biopsy sites compared to three in histological follow-up of eosinophilic esophagitis – A multicentric study. Digestive and Liver Disease. 2026. doi:10.1016/j.dld.2026.01.219

BibTeX
@article{Calabrese2026,
  author = {Calabrese, Francesco and Pasta, Andrea and Furnari, Manuele and Bodini, Giorgia and Grillo, Federica and Mastracci, Luca and Sorge, Andrea and Coletta, Marina and Penagini, Roberto and Vecchi, Maurizio and Marinoni, Beatrice and Aldinio, Giovanni and Pessarelli, Tommaso and Visaggi, Pierfrancesco and De Bortoli, Nicola and Maniero, Daria and Giannini, Edoardo Giovanni and Savarino, Edoardo Vincenzo and Marabotto, Elisa},
  title = {Evaluation of the diagnostic accuracy of two esophageal biopsy sites compared to three in histological follow-up of eosinophilic esophagitis – A multicentric study},
  journal = {Digestive and Liver Disease},
  year = {2026},
  doi = {10.1016/j.dld.2026.01.219}
}
Kostenlos starten →