Simultaneous pulmonary ventilation and perfusion imaging using spectral photon counting CT with xenon and gadolinium-based agents in combination with color K-edge imaging
Diagnostic and Interventional Imaging · 2026
DOI: 10.1016/j.diii.2026.06.003 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostic and Interventional Imaging, 2026. Verfasst von Antoine Robert und 15 weiteren Autor:innen. Beteiligte Einrichtung: INSA-Lyon, Université Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1294, 69500 Lyon, France. Hauptthemen laut MEDLINE: Xenon, Contrast Media, Gadolinium, Perfusion Imaging. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Research Council, H2020 European Research Council.
Abstract (Originalsprache)
PURPOSE: The purpose of this study was to assess the feasibility of color K-edge imaging enabled by spectral photon-counting CT (SPCCT) for simultaneous ventilation-perfusion evaluation using xenon and a gadolinium-based agent within healthy rabbit lungs. MATERIALS AND METHODS: In this animal study, a clinical SPCCT prototype was used to perform lung imaging in five New Zealand white rabbits. A phantom study was performed to assess gadolinium quantification accuracy and cross-contamination. Animals underwent controlled mechanical ventilation with xenon gas wash-in and received an intravenous injection of a gadolinium-based ultrasmall rigid platform (USRP) (dose, 2.3 mL·kg-1; injection rate, 3 mL·s-1; concentration, 0.29 mmol Gd.mL-1). Material decomposition yielded specific xenon and gadolinium K-edge images. Xenon maps were validated against dynamic specific ventilation maps using Pearson correlation test and linear regression analysis. Regional lung distribution was analyzed using Kruskal-Wallis test. RESULTS: Five rabbits (mean weight, 2.9 ± 0.06 [standard deviation] kg) were evaluated. In phantoms, measured gadolinium concentrations showed a perfect linear correlation with prepared concentrations (R2 = 1). In vivo, normalized steady-state xenon maps demonstrated a strong correlation with specific ventilation maps, with a pooled Pearson correlation coefficient of 0.88 and a pooled R2 of 0.78. Simultaneous imaging revealed a homogeneous xenon distribution with a median value across rabbits of 60.2% (first quartile [Q1], 59.3%; third quartile [Q3], 67.9%), with no significant regional differences. The median gadolinium perfusion across rabbits was 6.1% (Q1, 3.0%; Q3, 7.1%), with a significant dorsal-ventral gradient (P < 0.05) where the median value increased from 0.2% (Q1, -0.2%; Q3, 1.3%) in ventral regions to 6.9% (Q1, 3.8%; Q3, 10.6%) in dorsal regions. CONCLUSION: Color K-edge xenon/gadolinium-enhanced lung imaging using SPCCT is feasible in healthy animals, enabling the simultaneous specific and quantitative imaging of lung gas and blood volume.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- INSA-Lyon, Université Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1294, 69500 Lyon, France.
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, 20133 Milan, Italy.
- Philips GmbH Innovative Technologies, 22335 Hamburg, Germany.
- Philips Healthcare, 92150 Suresnes, France.
- Centre d'Etude et de Recherche Multimodal et Pluridisciplinaire en imagerie du vivant (CERMEP), 69500 Bron, France.
- INSA-Lyon, Université Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1294, 69500 Lyon, France; Department of Cardiovascular and Thoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, 69500 Bron, France.
Förderung
- European Research Council
- H2020 European Research Council
Zitieren
APA
Robert, A., Poletto, S., Erhard, K., Antonuccio, M. N., Hernandez, C. A., Gutwinska, A., Coulibaly, R. S., Davaux, F., Langlois, J. B., Boussel, L., Douek, P., Cottin, V., Rit, S., Dellacà, R. L., Bayat, S., & Si-Mohamed, S. A. (2026). Simultaneous pulmonary ventilation and perfusion imaging using spectral photon counting CT with xenon and gadolinium-based agents in combination with color K-edge imaging. Diagnostic and Interventional Imaging. https://doi.org/10.1016/j.diii.2026.06.003
Vancouver
Robert A, Poletto S, Erhard K, Antonuccio MN, Hernandez CA, Gutwinska A, et al. Simultaneous pulmonary ventilation and perfusion imaging using spectral photon counting CT with xenon and gadolinium-based agents in combination with color K-edge imaging. Diagnostic and Interventional Imaging. 2026. doi:10.1016/j.diii.2026.06.003
BibTeX
@article{Robert2026,
author = {Robert, Antoine and Poletto, Sofia and Erhard, Klaus and Antonuccio, Maria Nicole and Hernandez, Christian A and Gutwinska, Agnieszka and Coulibaly, Ramata Seydou and Davaux, Florian and Langlois, Jean-Baptiste and Boussel, Loic and Douek, Philippe and Cottin, Vincent and Rit, Simon and Dellacà, Raffaele L and Bayat, Sam and Si-Mohamed, Salim A},
title = {Simultaneous pulmonary ventilation and perfusion imaging using spectral photon counting CT with xenon and gadolinium-based agents in combination with color K-edge imaging},
journal = {Diagnostic and Interventional Imaging},
year = {2026},
doi = {10.1016/j.diii.2026.06.003}
}
EUVIMED