Color K-edge angiography with a dedicated gadolinium-based contrast agent for spectral photon-counting computed tomography
Diagnostic and Interventional Imaging · 2025
DOI: 10.1016/j.diii.2025.07.001 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostic and Interventional Imaging, 2025. Verfasst von Christian Alejandro Hernandez-Fajardo und 12 weiteren Autor:innen. Beteiligte Einrichtung: University of Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, 69621, 69100 Villeurbanne,…. Hauptthemen laut MEDLINE: Contrast Media, Gadolinium, Computed Tomography Angiography, Organometallic Compounds. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: French National Research Agency, European Research Council.
Abstract (Originalsprache)
PURPOSE: The purpose of this study was to investigate the feasibility of using a gadolinium (Gd)-based ultrasmall rigid platform (USRP) for angiography imaging using color K-edge imaging with spectral photon-counting CT technology in a rabbit model. MATERIALS AND METHODS: Ten atherosclerotic rabbits with a mean weight of 3.1 ± 0.5 (standard deviation) kg, underwent intravenous administration of an USRP solution (15 mL; 2.5 mL/s; 0.27 mol Gd3+/L). A sub-group of six rabbits also received gadoteric acid (7.8 mL; 1.4 mL/s; 0.5 mol Gd3+/L) for paired comparisons. Rabbits were imaged using a clinical SPCCT prototype (120 kVp; 100 mAs; 0.5-s rotation time; 1.17 pitch). The whole aorta was scanned 6 s post-injection (first pass), followed by abdominal scanning at 30 s, 1-, 3- and 10 min. Two-readers assigned aneurysm grades (expressed as a % vessel dilatation). Median, 25th, and 75th percentiles were used to compare first-pass signals. Mean signal differences in biodistribution for both agents were compared in the aorta, vena cava, and renal pelvis using t-test or Wilcoxon signed-rank test. Signals from both conventional CT and color K-edge images were analyzed. RESULTS: Mean aneurysm grades for both image types were 45 %. A matching first-pass signal was achieved for both agents (P = 0.98), with median concentrations of 7.8 mg/mL (6.9, 8.4) vs. 7.6 mg/mL (6.4, 8.6) for USRP and gadoteric acid, respectively. Following timepoints showed similar blood pool signal among agents, but a minimal increase in average signal (mean signal difference = 17 Hounsfield unit or 0.2 mg/mL; P 0.05). CONCLUSION: Gd-based USRPs can be used for color K-edge angiography imaging, representing viable contrast media candidates for emerging spectral photon-counting CT applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- University of Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, 69621, 69100 Villeurbanne, France.
- Universite Claude Bernard Lyon 1, CNRS, Institut Lumière-Matière (ILM), UMR 5306, 69622 Villeurbanne Cedex, France; Institut Universitaire de France (IUF), Paris, France.
- NH TherAGuIX SA, 38240 Meylan, France.
- CERMEP, Imagerie du Vivant, 69500 Bron, France.
- Universite Claude Bernard Lyon 1, CNRS, Institut Lumière-Matière (ILM), UMR 5306, 69622 Villeurbanne Cedex, France.
- University of Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, 69621, 69100 Villeurbanne, France; Department of Cardiovascular and Thoracic Radiology, Louis Pr…
Förderung
- French National Research Agency
- European Research Council
Zitieren
APA
Hernandez-Fajardo, C. A., Lux, F., Doussineau, T., Dufort, S., Langlois, J. B., Houmeau, A., Gutwinska, A., Coulibaly, R. S., Robert, A., Duc, G. L., Tillement, O., Douek, P., & Si-Mohamed, S. (2025). Color K-edge angiography with a dedicated gadolinium-based contrast agent for spectral photon-counting computed tomography. Diagnostic and Interventional Imaging. https://doi.org/10.1016/j.diii.2025.07.001
Vancouver
Hernandez-Fajardo CA, Lux F, Doussineau T, Dufort S, Langlois JB, Houmeau A, et al. Color K-edge angiography with a dedicated gadolinium-based contrast agent for spectral photon-counting computed tomography. Diagnostic and Interventional Imaging. 2025. doi:10.1016/j.diii.2025.07.001
BibTeX
@article{HernandezFajardo2025,
author = {Hernandez-Fajardo, Christian Alejandro and Lux, François and Doussineau, Tristan and Dufort, Sandrine and Langlois, Jean-Baptiste and Houmeau, Angele and Gutwinska, Agnieszka and Coulibaly, Ramata Seydou and Robert, Antoine and Duc, Geraldine Le and Tillement, Olivier and Douek, Philippe and Si-Mohamed, Salim},
title = {Color K-edge angiography with a dedicated gadolinium-based contrast agent for spectral photon-counting computed tomography},
journal = {Diagnostic and Interventional Imaging},
year = {2025},
doi = {10.1016/j.diii.2025.07.001}
}
EUVIMED