Lung shunt fraction calculations before Y-90 transarterial radioembolization: Comparison of accuracy and clinical significance of planar scintigraphy and SPECT/CT
Diagnostic and Interventional Imaging · 2023-04 · 104 (4) · 185-191
DOI: 10.1016/j.diii.2022.12.002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostic and Interventional Imaging, 2023-04. Verfasst von Shamar Young und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging, Division of Interventional Radiology, University of Arizona, Tucson, AZ 85724, USA. Hauptthemen laut MEDLINE: Liver Neoplasms, Embolization, Therapeutic, Carcinoma, Hepatocellular. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To determine the accuracy and clinical significance of planar scintigraphy lung shunt fraction (PLSF) and single-photon emission computerized tomography (SPECT) computed tomography (CT) lung shunt fraction (SLSF) before Y-90 transarterial radioembolization. MATERIALS AND METHODS: Seventy patients (46 men, 24 women; mean age, 64 ± 9.5 [SD] years) who underwent 83 treatments with Y-90 transarterial radioembolization for primary or secondary malignancies of the liver with a PLSF ≥ 7.5% were retrospectively evaluated. The patients mapping technetium 99 m (Tc-99 m) macroaggregated albumin (MAA) PLSF and SLSF were calculated and compared to the post Y-90 delivery SLSF. A model using modern dose thresholds was created to identify patients who would require dose reduction due to a lung dose ≥ 30 Gy, with patients who required >50% dose reduction considered to be delivery cancelations. RESULTS: A significant difference was found between mean PLSF (14.7 ± 11.6 [SD]%; range: 7.5-84.1%) and mean SLSF (8.7 ± 8.5 [SD]%; range: 1.7-73.5) (P < 0.001). The mean realized LSF (7.1 ± 3 [SD]%; range:1.5-17.6) was significantly less than the PLSF (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medical Imaging, Division of Interventional Radiology, University of Arizona, Tucson, AZ 85724, USA.
- Department of Radiology, Division of Interventional Radiology, University of Minnesota, Minneapolis, MN 55455, USA.
- Department of Radiology, Arizona Veterans Administration Hospital, Minneapolis, MN 55417, USA.
Zitieren
APA
Young, S., Flanagan, S., D'Souza, D., Todatry, S., Ragulojan, R., Sanghvi, T., & Golzarian, J. (2023). Lung shunt fraction calculations before Y-90 transarterial radioembolization: Comparison of accuracy and clinical significance of planar scintigraphy and SPECT/CT. Diagnostic and Interventional Imaging, 104(4), 185-191. https://doi.org/10.1016/j.diii.2022.12.002
Vancouver
Young S, Flanagan S, D'Souza D, Todatry S, Ragulojan R, Sanghvi T, et al. Lung shunt fraction calculations before Y-90 transarterial radioembolization: Comparison of accuracy and clinical significance of planar scintigraphy and SPECT/CT. Diagnostic and Interventional Imaging. 2023;104(4):185-191. doi:10.1016/j.diii.2022.12.002
BibTeX
@article{Young2023,
author = {Young, Shamar and Flanagan, Siobhan and D'Souza, Donna and Todatry, Soorya and Ragulojan, Ranjan and Sanghvi, Tina and Golzarian, Jafar},
title = {Lung shunt fraction calculations before Y-90 transarterial radioembolization: Comparison of accuracy and clinical significance of planar scintigraphy and SPECT/CT},
journal = {Diagnostic and Interventional Imaging},
year = {2023},
volume = {104},
number = {4},
pages = {185--191},
doi = {10.1016/j.diii.2022.12.002}
}