In-use energy-monitoring data from a retrofitted heritage building: Three dwellings with boiler, heat pump and ventilation systems
Data in Brief · 2025-12 · 63 · 112121
DOI: 10.1016/j.dib.2025.112121 ↗Kurz gefasst
Fachartikel in der Zeitschrift Data in Brief, 2025-12. Verfasst von Catalina Giraldo-Soto und 3 weiteren Autor:innen. Beteiligte Einrichtung: ENEDI research group, department of Energy Engineering. Faculty of Engineering of Bilbao, University of Basque Country (UPV/EHU). Pl. Ingeniero Torre…. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Spain Ministry of Science and Innovation, Euskal Herriko Unibertsitatea, European Regional Development Fund.
Abstract (Originalsprache)
An intensive Energy Monitoring and Control System (MCS) was installed in three dwellings of a retrofitted heritage building in Vitoria-Gasteiz (Spain) under the European project ENERPAT-SUDOE: Experimentation in the Eco-Renovation of Old Built Heritage. Two complementary MCS platforms-a fixed system and a mobile system-were deployed to support a range of experimental tests aimed at assessing the building's energy performance and the effectiveness of its energy systems post-retrofit. The datasets derived from an experimental work that implemented two Monitoring and Control System (MCS), a fixed and mobile MCS, which were implemented to conduct different experimental test to assess the energy performance of building and their energy systems after the eco-retrofitting. This Data in Brief includes data from the fixed MCS, where the data from this MCS complements the dataset derived from the mobile MCS. The datasets of the fixed MCS were compiled through a rigorous data collection process, with 81 sensors installed to collect data from October 26, 2019, at 13:53:00 to November 05, 2024, at 23:59:00. These datasets provide valuable insights into the energy performance of the monitored dwellings, capturing physical variables of user comfort, heating and HVAC system, electrical energy consumption, and weather conditions. Moreover, the data can be leveraged to optimize monitoring and control strategies for Building Automation Systems (BAS), heating systems, and HVAC systems. Additionally, it supports the advancement of research methodologies that rely on Key Performance Indicators of building energy behaviour, such as the Heat Transfer Coefficient (HTC). Companion dataset: controlled envelope-testing data (co-heating, QUB, ISO-9869) from the same building using a mobile MCS (Manuscript ID DIB-d-25-01,295).
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- ENEDI research group, department of Energy Engineering. Faculty of Engineering of Bilbao, University of Basque Country (UPV/EHU). Pl. Ingeniero Torres Quevedo 1, 48013 Bilbao, Spain.
- TECNALIA, Basque Research and Technology Alliance (BRTA), Edificio 700 Parque Tecnológico de Bizkaia, Derio, Spain.
Förderung
- Spain Ministry of Science and Innovation
- Euskal Herriko Unibertsitatea
- European Regional Development Fund
- Edge Hill University
- Eusko Jaurlaritza
- Université de Bordeaux
Zitieren
APA
Giraldo-Soto, C., Erkoreka, A., Uriarte, A., & Flores-Abascal, I. (2025). In-use energy-monitoring data from a retrofitted heritage building: Three dwellings with boiler, heat pump and ventilation systems. Data in Brief, 63, 112121. https://doi.org/10.1016/j.dib.2025.112121
Vancouver
Giraldo-Soto C, Erkoreka A, Uriarte A, Flores-Abascal I. In-use energy-monitoring data from a retrofitted heritage building: Three dwellings with boiler, heat pump and ventilation systems. Data in Brief. 2025;63:112121. doi:10.1016/j.dib.2025.112121
BibTeX
@article{GiraldoSoto2025,
author = {Giraldo-Soto, Catalina and Erkoreka, Aitor and Uriarte, Amaia and Flores-Abascal, Ivan},
title = {In-use energy-monitoring data from a retrofitted heritage building: Three dwellings with boiler, heat pump and ventilation systems},
journal = {Data in Brief},
year = {2025},
volume = {63},
pages = {112121},
doi = {10.1016/j.dib.2025.112121}
}
EUVIMED