EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A dataset of hemoglobin blood value and photoplethysmography signal for machine learning-based non-invasive hemoglobin measurement

Tomy Abuzairi, Ester Vinia, Muhammad Arkana Yudhistira, Mia Rizkinia, Winda Eriska

Data in Brief · 2024-02 · 52 · 109823

DOI: 10.1016/j.dib.2023.109823 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Data in Brief, 2024-02. Verfasst von Tomy Abuzairi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Electrical Engineering, Department of Electrical Engineering, Faculty of Engineering, Universitas Indonesia, Depok 16424, Indonesia. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Indonesia Directorate of Research and Development, Universitas Indonesia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hemoglobin (Hb), a protein found within red blood cells, is responsible for transporting oxygen and carbon dioxide gasses. A low concentration of Hb indicates the existence of anemia. Traditional invasive Hb examination methods are accurate but have drawbacks, such as pain. A new approach, non-invasive photoplethysmography (PPG), addresses these issues and allows real-time Hb examination. In this article, the dataset consists of PPG signal, gender, age, and Hb value. The PPG signal was measured by a MAX30102 module sensor that emitted two types of light (red and infra-red light) and measured using a photodetector. Total of 68 subjects (56% female and 44% male) within the age of 18-65 years were collected. The total dataset is 816 data from 68 subjects, which each subject provides 12 sets of red and infra-red light signals. The data were collected at Primary Health Center Jatiuwung, Tangerang City, Banten 15,138, Indonesia. Researchers interested in anemia monitoring and those pursuing the development of non-invasive hemoglobin measurement based on machine learning can leverage this dataset.

Schlagwörter

Stichwörter der Autor:innen

DatasetHemoglobinMachine learningNon-invasivePhotoplethysmography

Autor:innen und Institutionen

  • Electrical Engineering, Department of Electrical Engineering, Faculty of Engineering, Universitas Indonesia, Depok 16424, Indonesia.
  • Biomedical Engineering, Department of Electrical Engineering, Faculty of Engineering, Universitas Indonesia, Depok 16424, Indonesia.
  • Computer Engineering, Department of Electrical Engineering, Faculty of Engineering, Universitas Indonesia, Depok 16424, Indonesia.
  • Faculty of Nursing, Universitas Indonesia, Depok 16424, Indonesia.

Förderung

  • University of Indonesia Directorate of Research and Development
  • Universitas Indonesia

Zitieren

APA

Abuzairi, T., Vinia, E., Yudhistira, M. A., Rizkinia, M., & Eriska, W. (2024). A dataset of hemoglobin blood value and photoplethysmography signal for machine learning-based non-invasive hemoglobin measurement. Data in Brief, 52, 109823. https://doi.org/10.1016/j.dib.2023.109823

Vancouver

Abuzairi T, Vinia E, Yudhistira MA, Rizkinia M, Eriska W. A dataset of hemoglobin blood value and photoplethysmography signal for machine learning-based non-invasive hemoglobin measurement. Data in Brief. 2024;52:109823. doi:10.1016/j.dib.2023.109823

BibTeX
@article{Abuzairi2024,
  author = {Abuzairi, Tomy and Vinia, Ester and Yudhistira, Muhammad Arkana and Rizkinia, Mia and Eriska, Winda},
  title = {A dataset of hemoglobin blood value and photoplethysmography signal for machine learning-based non-invasive hemoglobin measurement},
  journal = {Data in Brief},
  year = {2024},
  volume = {52},
  pages = {109823},
  doi = {10.1016/j.dib.2023.109823}
}
Kostenlos starten →