EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Indoor air quality and particulate matter exposure in early childhood centres under natural ventilation and air-conditioned operation in Lampang, Thailand

Pantitcha Thanatrakolsri, Butsabamintra Labutdi, Sawanya Khumsuk, Kanchana Khamphakhiao

Dialogues in Health · 2026-12 · 9 · 100369

DOI: 10.1016/j.dialog.2026.100369 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Dialogues in Health, 2026-12. Verfasst von Pantitcha Thanatrakolsri und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Public Health, Thammasat University, Lampang 52190, Thailand. Die Arbeit nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Air pollution, particularly fine and coarse particulate matter including PM2.5 and PM10, poses an important health concern for young children. This cross-sectional observational study characterised indoor air quality and particulate exposure in early childhood development centres under routine non-haze conditions, comparing morning natural-ventilation periods with afternoon air-conditioned periods. PM2.5 and PM10 measurements were used to estimate 5-h time-weighted average concentrations (TWA5h), inhaled particulate mass, and body-weight-normalised exposure doses among children aged under 3 years. A scenario-based analysis compared the observed mixed daily operating schedule with hypothetical conditions of continuous natural ventilation and continuous air-conditioned operation. PM2.5 concentrations were lower during the afternoon air-conditioned period than during the morning natural-ventilation period across all eight comparison units, while PM10 concentrations were lower in seven comparison units but higher in one. Mean CO2 concentrations were higher during the afternoon air-conditioned period across all eight comparison units. Estimated PM10 doses exceeded PM2.5 doses across all centres, and scenario-based estimates showed more consistent reductions for PM2.5 than for PM10 under continuous air-conditioned operation. Because ventilation condition coincided with time of day and outdoor particulate measurements were incomplete, the observed differences cannot be attributed solely to ventilation condition or specific particle sources. These findings indicate that indoor air-quality management should jointly address particulate control and adequate outdoor-air provision, together with filtration, indoor source control, and regular system maintenance.

Schlagwörter

Stichwörter der Autor:innen

Air-conditioned operationBioaerosolEarly childhood settingsExposure assessmentIndoor air quality

Autor:innen und Institutionen

  • Faculty of Public Health, Thammasat University, Lampang 52190, Thailand.
  • Thammasat University Research Unit in Environment, Health and Epidemiology, Lampang 52190, Thailand.

Zitieren

APA

Thanatrakolsri, P., Labutdi, B., Khumsuk, S., & Khamphakhiao, K. (2026). Indoor air quality and particulate matter exposure in early childhood centres under natural ventilation and air-conditioned operation in Lampang, Thailand. Dialogues in Health, 9, 100369. https://doi.org/10.1016/j.dialog.2026.100369

Vancouver

Thanatrakolsri P, Labutdi B, Khumsuk S, Khamphakhiao K. Indoor air quality and particulate matter exposure in early childhood centres under natural ventilation and air-conditioned operation in Lampang, Thailand. Dialogues in Health. 2026;9:100369. doi:10.1016/j.dialog.2026.100369

BibTeX
@article{Thanatrakolsri2026,
  author = {Thanatrakolsri, Pantitcha and Labutdi, Butsabamintra and Khumsuk, Sawanya and Khamphakhiao, Kanchana},
  title = {Indoor air quality and particulate matter exposure in early childhood centres under natural ventilation and air-conditioned operation in Lampang, Thailand},
  journal = {Dialogues in Health},
  year = {2026},
  volume = {9},
  pages = {100369},
  doi = {10.1016/j.dialog.2026.100369}
}
Kostenlos starten →