Sequentially offset silicone palatal obturators designed from CBCT data for provisional rehabilitation of centrally located maxillary defects: A preliminary clinical workflow study
Digital Dentistry Journal · 2026-12 · 4 (1) · 100105
DOI: 10.1016/j.ddj.2026.100105 ↗Kurz gefasst
Fachartikel in der Zeitschrift Digital Dentistry Journal, 2026-12. Verfasst von Sergi Torné-Durán und 2 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objectives
To describe and clinically evaluate a hybrid cone beam computed tomography (CBCT)-based workflow for designing and fabricating sequentially offset silicone palatal obturators for provisional rehabilitation of centrally located maxillary defects.
Methods
Five consecutive patients with Aramany Class III maxillary defects were treated without conventional impressions. CBCT datasets were segmented to generate 3-dimensional surface models of the palatal defect. These models were used to design hollow, self-retentive silicone obturator bulbs. Additional obturators were digitally preprogrammed with controlled outward surface offsets of 0.2 mm, 0.4 mm, and 0.6 mm to compensate for tissue remodeling during healing. Patients were followed monthly during the 6-month provisional rehabilitation period, and devices were replaced according to clinical retention and sealing rather than at fixed time intervals.
Results
The baseline 0 mm obturator did not provide adequate self-retention in any patient. Stable mechanical retention and functional sealing were achieved using either the 0.2 mm or 0.4 mm offset obturators in all patients. The 0.6 mm offset was not required. Progressive loss of retention during healing was managed by replacing the obturator with the next preprogrammed offset, usually after approximately 1 to 2 months depending on individual clinical evolution. No additional impressions or imaging were required during the sequential offset phase, and no adverse events were observed.
Conclusions
This CBCT-based sequential offset workflow appears to be a feasible approach for provisional rehabilitation of centrally located maxillary defects. The technique enabled early obturator placement, progressive adaptation during healing, and functional sealing without conventional impressions or repeated imaging. Clinical Significance CBCT-derived sequentially offset silicone obturators may simplify provisional rehabilitation of centrally located maxillary defects by avoiding conventional impressions, reducing patient discomfort, and maintaining retention during healing. This workflow may be especially useful when impression procedures are contraindicated, poorly tolerated, or clinically impractical because of oro-nasal communication or complex undercut anatomy.
Zitieren
APA
Torné-Durán, S., Roca, J. M. M., & Escuin-Henar, T. (2026). Sequentially offset silicone palatal obturators designed from CBCT data for provisional rehabilitation of centrally located maxillary defects: A preliminary clinical workflow study. Digital Dentistry Journal, 4(1), 100105. https://doi.org/10.1016/j.ddj.2026.100105
Vancouver
Torné-Durán S, Roca JMM, Escuin-Henar T. Sequentially offset silicone palatal obturators designed from CBCT data for provisional rehabilitation of centrally located maxillary defects: A preliminary clinical workflow study. Digital Dentistry Journal. 2026;4(1):100105. doi:10.1016/j.ddj.2026.100105
BibTeX
@article{TornDurn2026,
author = {Torné-Durán, Sergi and Roca, J. Miguel Mayos and Escuin-Henar, Tomás},
title = {Sequentially offset silicone palatal obturators designed from CBCT data for provisional rehabilitation of centrally located maxillary defects: A preliminary clinical workflow study},
journal = {Digital Dentistry Journal},
year = {2026},
volume = {4},
number = {1},
pages = {100105},
doi = {10.1016/j.ddj.2026.100105}
}
EUVIMED