EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Dynamic energy analysis of rooftop Greenhouse–Integrated building according to cooling scenarios of rooftop greenhouses for energy saving

Jeong-Hwa Cho, Sang Min Lee, Sangseok Yu

Case Studies in Thermal Engineering · 2025-11 · 75 · 107115

DOI: 10.1016/j.csite.2025.107115 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Case Studies in Thermal Engineering, 2025-11. Verfasst von Jeong-Hwa Cho und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Ministry of Trade, Industry and Energy, Korea Institute of Energy Technology Evaluation and Planning.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rooftop greenhouses (RTGs) can mitigate the increasing building energy of the abnormal climate and continuing urbanisation. When the external temperature is low, the heating energy consumption of the building’s top floor can be reduced due to the thermal insulation effect provided by the RTG. However, the cooling operation requires elaborate efforts to reduce the total energy consumption of the building and RTG. Thus, according to the cooling scenario of the greenhouse, energy savings of model featuring RTG-structurally integrated building are compared with those of a separately located greenhouse and building. To this end, the validated greenhouse model is employed to analyse the scenario for the lowest energy consumption. The heat pump capacity to maintain the structurally separate greenhouse under optimal crop-growing conditions is simulated based on the energy consumption of the heat pump. Consequently, operating a rooftop greenhouse with forced ventilation during the summer results in an annual energy savings of 44.9% for the top floor of an adjacent building. By suspending crop cultivation during the hot season, building energy consumption can be reduced by up to 60.2% annually. By effectively operating the RTG, the total energy required by greenhouses and buildings can be saved and carbon emissions can be reduced.

Förderung

  • Ministry of Trade, Industry and Energy
  • Korea Institute of Energy Technology Evaluation and Planning

Zitieren

APA

Cho, J., Lee, S. M., & Yu, S. (2025). Dynamic energy analysis of rooftop Greenhouse–Integrated building according to cooling scenarios of rooftop greenhouses for energy saving. Case Studies in Thermal Engineering, 75, 107115. https://doi.org/10.1016/j.csite.2025.107115

Vancouver

Cho J, Lee SM, Yu S. Dynamic energy analysis of rooftop Greenhouse–Integrated building according to cooling scenarios of rooftop greenhouses for energy saving. Case Studies in Thermal Engineering. 2025;75:107115. doi:10.1016/j.csite.2025.107115

BibTeX
@article{Cho2025,
  author = {Cho, Jeong-Hwa and Lee, Sang Min and Yu, Sangseok},
  title = {Dynamic energy analysis of rooftop Greenhouse–Integrated building according to cooling scenarios of rooftop greenhouses for energy saving},
  journal = {Case Studies in Thermal Engineering},
  year = {2025},
  volume = {75},
  pages = {107115},
  doi = {10.1016/j.csite.2025.107115}
}
Kostenlos starten →