EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparison of an AI-driven planning tool and manual radiographic measurements in total knee arthroplasty

Marie Theres Heller, Guenther Maderbacher, Marie Farina Schuster, Lina Forchhammer, Markus Scharf, Tobias Renkawitz, Stefano Pagano

Computational and Structural Biotechnology Journal · 2025-01 · 28 · 148-155

DOI: 10.1016/j.csbj.2025.04.009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computational and Structural Biotechnology Journal, online erschienen am 15.04.2025. Verfasst von Marie Theres Heller und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, University of Regensburg, Asklepios Klinikum, Bad Abbach, Germany. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, Deutschen Arthrose-Hilfe, Bundesministerium für Bildung und Forschung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accurate preoperative planning in total knee arthroplasty (TKA) is essential. Traditional manual radiographic planning can be time-consuming and potentially prone to inaccuracies. This study investigates the performance of an AI-based radiographic planning tool in comparison with manual measurements in patients undergoing total knee arthroplasty, using a retrospective observational design to assess reliability and efficiency.

Methods

We retrospectively compared the Autoplan tool integrated within the mediCAD software (mediCAD Hectec GmbH, Altdorf, Germany), routinely implemented in our institutional workflow, to manual measurements performed by two orthopedic specialists on pre- and postoperative radiographs of 100 patients who underwent elective TKA. The following parameters were measured: leg length, mechanical axis deviation (MAD), mechanical lateral proximal femoral angle (mLPFA), anatomical mechanical angle (AMA), mechanical lateral distal femoral angle (mLDFA), joint line convergence angle (JLCA), mechanical medial proximal tibial angle (mMPTA), and mechanical tibiofemoral angle (mTFA). Intraclass correlation coefficients (ICCs) were calculated to assess measurement reliability, and the time required for each method was recorded.

Results

The Autoplan tool demonstrated high reliability (ICC > 0.90) compared with manual measurements for linear parameters (e.g., leg length and MAD). However, the angular measurements of mLPFA, JLCA, and AMA exhibited poor reliability (ICC < 0.50) among all raters. The Autoplan tool significantly reduced the time required for measurements compared to manual measurements, with a mean time saving of 44.3 seconds per case (95 % CI: 43.5–45.1 seconds, p < 0.001).

Conclusion

AI-assisted tools like the Autoplan tool in mediCAD offer substantial time savings and demonstrate reliable measurements for certain linear parameters in preoperative TKA planning. However, the observed low reliability in some measurements, even amongst experienced human raters, suggests inherent challenges in the radiographic assessment of angular parameters. Further development is needed to improve the accuracy of automated angular measurements, and to address the inherent variability in their assessment.

Schlagwörter

Stichwörter der Autor:innen

Artificial IntelligenceAutomated PlanningIntraclass Correlation CoefficientMeasurement EfficiencyRadiographic MeasurementTotal Knee Arthroplasty

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, University of Regensburg, Asklepios Klinikum, Bad Abbach, Germany.

Förderung

  • Deutsche Forschungsgemeinschaft
  • Deutschen Arthrose-Hilfe
  • Bundesministerium für Bildung und Forschung

Zitieren

APA

Heller, M. T., Maderbacher, G., Schuster, M. F., Forchhammer, L., Scharf, M., Renkawitz, T., & Pagano, S. (2025). Comparison of an AI-driven planning tool and manual radiographic measurements in total knee arthroplasty. Computational and Structural Biotechnology Journal, 28, 148-155. https://doi.org/10.1016/j.csbj.2025.04.009

Vancouver

Heller MT, Maderbacher G, Schuster MF, Forchhammer L, Scharf M, Renkawitz T, et al. Comparison of an AI-driven planning tool and manual radiographic measurements in total knee arthroplasty. Computational and Structural Biotechnology Journal. 2025;28:148-155. doi:10.1016/j.csbj.2025.04.009

BibTeX
@article{Heller2025,
  author = {Heller, Marie Theres and Maderbacher, Guenther and Schuster, Marie Farina and Forchhammer, Lina and Scharf, Markus and Renkawitz, Tobias and Pagano, Stefano},
  title = {Comparison of an AI-driven planning tool and manual radiographic measurements in total knee arthroplasty},
  journal = {Computational and Structural Biotechnology Journal},
  year = {2025},
  volume = {28},
  pages = {148--155},
  doi = {10.1016/j.csbj.2025.04.009}
}
Kostenlos starten →