EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Harmonizing TUNEL with multiplexed iterative immunofluorescence enriches spatial contextualization of cell death

Marc S Sherman, Thomas McMahon-Skates, Lindsey S Gaston, Sonya W Katzen, Joseph A Majzoub, Wolfram Goessling

Cell Reports Methods · 2025-05 · 5 (5) · 101047

DOI: 10.1016/j.crmeth.2025.101047 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cell Reports Methods, 2025-05. Verfasst von Marc S Sherman und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Gastroenterology, Department of Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA; Division of Genetics, …. Hauptthemen laut MEDLINE: In Situ Nick-End Labeling, Fluorescent Antibody Technique. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIH HHS, NIDDK NIH HHS, Boston Children's Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Terminal deoxynucleotidyl transferase dUTP nick-end labeling (TUNEL) is an essential tool for detecting cell death in tissues, but its compatibility with spatial proteomic methods is unknown. We evaluated variations of the TUNEL protocol for compatibility with multiple iterative labeling by antibody neodeposition (MILAN) in acetaminophen-induced hepatocyte necrosis and dexamethasone-induced adrenocortical apoptosis. Using a commercial Click-iT-based assay as a standard, TUNEL signal could be reliably produced independent of the antigen retrieval method, with tissue-specific minor differences in signal to noise. In contrast, proteinase K treatment consistently reduced or even abrogated protein antigenicity, while pressure cooker treatment enhanced protein antigenicity for the targets tested. Antibody-based TUNEL with pressure cooker retrieval could be flexibly integrated into a MILAN staining series, and first-round TUNEL was also compatible with a second spatial proteomic method, cyclic immunofluorescence (CycIF). We anticipate that this harmonization of TUNEL with spatial proteomics will enhance the spatial contextualization of cell death in complex tissues.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

In Situ Nick-End LabelingFluorescent Antibody TechniqueAnimalsApoptosisCell DeathHepatocytesProteomicsAcetaminophenDexamethasoneHumansNecrosis

Stichwörter der Autor:innen

CP: ImagingCycIFMILANTUNELacetaminophen liver toxicityapoptosiscell deathdexamethasone-induced adrenal insufficiencyproteinase Kspatial proteomicszonation

Substanzen

AcetaminophenDexamethasone

Autor:innen und Institutionen

  • Division of Gastroenterology, Department of Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA; Division of Genetics, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.…
  • Division of Genetics, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
  • Division of Endocrinology, Department of Pediatrics, Boston Children's Hospital, Boston, MA, USA.
  • Division of Gastroenterology, Department of Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
  • Division of Gastroenterology, Department of Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA; Division of Genetics, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA;…

Förderung

  • NIH HHS
  • NIDDK NIH HHS
  • Boston Children's Hospital
  • Pediatric Endocrine Society
  • National Institutes of Health
  • Beth Israel Deaconess Medical Center
  • National Institute of Diabetes and Digestive and Kidney Diseases

Zitieren

APA

Sherman, M. S., McMahon-Skates, T., Gaston, L. S., Katzen, S. W., Majzoub, J. A., & Goessling, W. (2025). Harmonizing TUNEL with multiplexed iterative immunofluorescence enriches spatial contextualization of cell death. Cell Reports Methods, 5(5), 101047. https://doi.org/10.1016/j.crmeth.2025.101047

Vancouver

Sherman MS, McMahon-Skates T, Gaston LS, Katzen SW, Majzoub JA, Goessling W. Harmonizing TUNEL with multiplexed iterative immunofluorescence enriches spatial contextualization of cell death. Cell Reports Methods. 2025;5(5):101047. doi:10.1016/j.crmeth.2025.101047

BibTeX
@article{Sherman2025,
  author = {Sherman, Marc S and McMahon-Skates, Thomas and Gaston, Lindsey S and Katzen, Sonya W and Majzoub, Joseph A and Goessling, Wolfram},
  title = {Harmonizing TUNEL with multiplexed iterative immunofluorescence enriches spatial contextualization of cell death},
  journal = {Cell Reports Methods},
  year = {2025},
  volume = {5},
  number = {5},
  pages = {101047},
  doi = {10.1016/j.crmeth.2025.101047}
}
Kostenlos starten →