Human health risk evaluation of a microwave-driven atmospheric plasma jet as medical device
Clinical Plasma Medicine · 2017-12 · 7-8 · 16-23
DOI: 10.1016/j.cpme.2017.06.001 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Plasma Medicine, 2017-12. Verfasst von A. Lehmann und 2 weiteren Autor:innen. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Zentrales Innovations Programm Mittelstand, BMWI.
Abstract (Originalsprache)
The aim of this study was the characterisation of a microwave-driven atmospheric plasma jet (APJ) dedicated for medical applications. The scientific focus includes harmless sterilization of surfaces and therapeutic treatments in dentistry. The plasma was investigated with respect to potential health risks for human beings, which could occur especially by the gas temperature, heat flow, patient leakage current, UV emission and ozone emission from the plasma jet, according to DIN SPEC 91315:2014-06 (General requirements for plasma sources in medicine) [1]. The results of the experiments indicate a high potential of the plasma jet to be used as a medical device exhibiting low gas temperatures up to 34 °C. The calculated leakage currents are mostly below the 10 μA threshold. The limiting UV exposure duration for the APJ with a calculated maximum effective irradiance of 2.6 μW/cm2 is around 19 min, based on the exposure limits of the international commission on non-ionizing radiation protection guidelines (ICNIRP) [2]. A significant ozone concentration was observed mainly in the axial effluent gas flow. Ozone concentration strongly decreases with increasing distance from the plasma source exit nozzle. The investigated APJ exhibits physical properties that might not constitute health risks to humans, e.g. during treatment in dentistry. Thus, the APJ shows a high potential for application as a device in dental therapy.
Förderung
- Zentrales Innovations Programm Mittelstand
- BMWI
Zitieren
APA
Lehmann, A., Pietag, F., & Arnold, T. (2017). Human health risk evaluation of a microwave-driven atmospheric plasma jet as medical device. Clinical Plasma Medicine, 7-8, 16-23. https://doi.org/10.1016/j.cpme.2017.06.001
Vancouver
Lehmann A, Pietag F, Arnold T. Human health risk evaluation of a microwave-driven atmospheric plasma jet as medical device. Clinical Plasma Medicine. 2017;7-8:16-23. doi:10.1016/j.cpme.2017.06.001
BibTeX
@article{Lehmann2017,
author = {Lehmann, A. and Pietag, F. and Arnold, Th.},
title = {Human health risk evaluation of a microwave-driven atmospheric plasma jet as medical device},
journal = {Clinical Plasma Medicine},
year = {2017},
volume = {7-8},
pages = {16--23},
doi = {10.1016/j.cpme.2017.06.001}
}
EUVIMED