EUVIMEDEUVIMED entdecken
Übersichtsarbeit

Receptor-PET and 2-deoxy-2-[18F]fluoro-d-glucose Concordance-discordance and Flip-flop Phenomenon

Sarina Shah, Sandip Basu

PET Clinics · 2026-11

DOI: 10.1016/j.cpet.2026.09.023 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift PET Clinics, 2026-11. Verfasst von Sarina Shah und 1 weiteren Autor:innen. Beteiligte Einrichtung: Radiation Medicine Centre, Bhabha Atomic Research Centre, Tata Memorial Hospital Annexe, Parel, 400012, Mumbai, India; Homi Bhabha National Institute…. Die Arbeit nennt 98 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With the development and expansion of new targeted radiotracers in Theranostics, defining the specific clinical indications for FDG-PET/CT is pivotal to personalised medicine and precision oncology. The "flip-flop" phenomenon refers to the reciprocal yet complementary relationship between lineage-specific receptor PET tracers and FDG PET/CT. However, in real-world scenarios, varying degrees of concordance between receptor-targeted PET and FDG-PET reflect a continuum rather than a binary classification. The concept of dual-tracer/multi-tracer PET, employed in neuroendocrine tumours and castration-resistant prostate cancer, is likely to influence treatment decision-making in other malignancies as well.

Schlagwörter

Stichwörter der Autor:innen

(177)Lu-PSMA-617 radioligand therapy (PRLT)FDG-PETFlip-flopPSMAPeptide receptor radionuclide therapy (PRRT)Receptor PETSSTR[(68)Ga]Ga-DOTATATE PET[(68)Ga]Ga-PSMA-11 PET/CT[(68)Ga]Ga-SSA PET/CT

Autor:innen und Institutionen

  • Radiation Medicine Centre, Bhabha Atomic Research Centre, Tata Memorial Hospital Annexe, Parel, 400012, Mumbai, India; Homi Bhabha National Institute, Mumbai, India.
  • Radiation Medicine Centre, Bhabha Atomic Research Centre, Tata Memorial Hospital Annexe, Parel, 400012, Mumbai, India; Homi Bhabha National Institute, Mumbai, India. Electronic address: drsanb@yahoo.com.

Zitieren

APA

Shah, S., & Basu, S. (2026). Receptor-PET and 2-deoxy-2-[18F]fluoro-d-glucose Concordance-discordance and Flip-flop Phenomenon. PET Clinics. https://doi.org/10.1016/j.cpet.2026.09.023

Vancouver

Shah S, Basu S. Receptor-PET and 2-deoxy-2-[18F]fluoro-d-glucose Concordance-discordance and Flip-flop Phenomenon. PET Clinics. 2026. doi:10.1016/j.cpet.2026.09.023

BibTeX
@article{Shah2026,
  author = {Shah, Sarina and Basu, Sandip},
  title = {Receptor-PET and 2-deoxy-2-[18F]fluoro-d-glucose Concordance-discordance and Flip-flop Phenomenon},
  journal = {PET Clinics},
  year = {2026},
  doi = {10.1016/j.cpet.2026.09.023}
}
Kostenlos starten →