EUVIMEDEUVIMED entdecken
Klinische Studie (Phase IV)VergleichsstudieRandomisierte kontrollierte Studie

Bleeding profile and safety of a levonorgestrel 13.5 mg intrauterine device versus Nova T copper 380 mm2 intrauterine device: Results of a 3-year, single-center, randomized phase 4 study

Josep Perelló-Capó, Josep Estadella-Tarriel, Ignasi Gich-Saladich, Marta Bailón-Queiruga, Elisa Llurba-Olivé, Joaquim Calaf-Alsina

Contraception · 2023-11 · 127 · 110127

DOI: 10.1016/j.contraception.2023.110127 ↗

Kurz gefasst

Klinische Studie (Phase IV) in der Zeitschrift Contraception, 2023-11. Verfasst von Josep Perelló-Capó und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain; Pediatrics, Obstetrics and Gynecology, and Preventiv…. Hauptthemen laut MEDLINE: Contraceptive Agents, Female, Dysmenorrhea, Intrauterine Devices, Copper, Intrauterine Devices, Medicated. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Bayer AG.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To assess the bleeding profiles of the levonorgestrel 13.5 mg intrauterine device (LNG13.5-IUD) and Nova T copper 380 mm2 IUD (Cu380-IUD). STUDY DESIGN: Single-center, evaluator-masked, randomized study conducted in women aged 18-45 years starting these methods. Primary outcomes were number of bleeding days, self-reported bleeding intensity, Pictorial Blood Assessment Chart (PBAC) score, and blood biochemical values at baseline, months 3, 6, 12, 24, and 36 per 90-day reference periods except for PBAC (months). Secondary objectives were presence/duration/intensity of dysmenorrhea and tolerability. RESULTS: We included 106 women aged 32.5 ± 6.7 years: 55 with LNG13.5-IUD and 51 with Cu380-IUD. Data for LNG13.5-IUD versus Cu380-IUD at baseline and month 36 (both respectively) were as follows: (1) median (25th; 75th percentile) number of bleeding days: 12 (9.0; 15.0) versus 12 (9.0; 15.0), p = 0.82, and 4 (0; 13.7) versus 15 (14.2; 20.0), p < 0.001; (2) mean bleeding intensity: 1.7 for both, p = 0.66, and 0.7 and 2.2, p < 0.001. Forty percent versus 0% presented with amenorrhea at month 36; (3) mean PBAC score (95% Confidence interval (CI): 50.7 (16.6; 84.7) versus 130.4 (95.7; 165.0) at month 1, and 7.9 (-26.7; 42.6) versus 126 (90.7; 161.2), p < 0.001; (4) median (25th; 75th percentile) ferritin levels (Ug/L) 33 (19; 53) versus 30 (19; 45), p = 0.70, and 59 (42; 84) versus 21 (8; 39). We did not observe changes or differences between groups in hemoglobin and hematocrit. The duration and intensity of dysmenorrhea were significantly lower with LNG13.5-IUD versus Cu380-IUD. Adverse events were those expected. CONCLUSIONS: LNG13.5-IUD is associated with a significant reduction in blood loss and dysmenorrhea compared with Cu380-IUD. IMPLICATIONS: Women eligible for a levonorgestrel 13.5 mg intrauterine device (IUD) or a copper 380 mm2 IUD should be informed of the differences in bleeding profiles-one of the main causes for IUD discontinuation-so they can compare this information against their bleeding expectations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contraceptive Agents, FemaleDysmenorrheaIntrauterine Devices, CopperIntrauterine Devices, MedicatedFemaleHumansCopperLevonorgestrelAdultMenstruation DisturbancesMenstruation

Stichwörter der Autor:innen

BleedingContraceptionCopper intrauterine contraceptive deviceHormonal contraceptionHormone-releasing intrauterine contraceptive deviceLong-acting reversible contraception

Substanzen

Contraceptive Agents, FemaleCopperLevonorgestrel

Autor:innen und Institutionen

  • Department of Obstetrics and Gynecology, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain; Pediatrics, Obstetrics and Gynecology, and Preventive Medicine and Public Health Department, Universitat Autònoma de Barce…
  • Clinical Epidemiology and Public Health Service, IIB Sant Pau, Universitat Autonoma de Barcelona, Barcelona, Spain.
  • Department of Obstetrics and Gynecology, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain.

Förderung

  • Bayer AG

Zitieren

APA

Perelló-Capó, J., Estadella-Tarriel, J., Gich-Saladich, I., Bailón-Queiruga, M., Llurba-Olivé, E., & Calaf-Alsina, J. (2023). Bleeding profile and safety of a levonorgestrel 13.5 mg intrauterine device versus Nova T copper 380 mm2 intrauterine device: Results of a 3-year, single-center, randomized phase 4 study. Contraception, 127, 110127. https://doi.org/10.1016/j.contraception.2023.110127

Vancouver

Perelló-Capó J, Estadella-Tarriel J, Gich-Saladich I, Bailón-Queiruga M, Llurba-Olivé E, Calaf-Alsina J. Bleeding profile and safety of a levonorgestrel 13.5 mg intrauterine device versus Nova T copper 380 mm2 intrauterine device: Results of a 3-year, single-center, randomized phase 4 study. Contraception. 2023;127:110127. doi:10.1016/j.contraception.2023.110127

BibTeX
@article{PerellCap2023,
  author = {Perelló-Capó, Josep and Estadella-Tarriel, Josep and Gich-Saladich, Ignasi and Bailón-Queiruga, Marta and Llurba-Olivé, Elisa and Calaf-Alsina, Joaquim},
  title = {Bleeding profile and safety of a levonorgestrel 13.5 mg intrauterine device versus Nova T copper 380 mm2 intrauterine device: Results of a 3-year, single-center, randomized phase 4 study},
  journal = {Contraception},
  year = {2023},
  volume = {127},
  pages = {110127},
  doi = {10.1016/j.contraception.2023.110127}
}
Kostenlos starten →