EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Expert practitioner accuracy and reliability when assessing a novel dynamic pelvic floor muscle simulator for tone and strength

Dominic Orth, Maia Heath, Lucia Berry, Paula Igualada-Martinez, Gabriella Spinelli

Continence · 2026-11 · 102922

DOI: 10.1016/j.cont.2026.102922 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Continence, 2026-11. Verfasst von Dominic Orth und 4 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Digital palpation is widely used to assess pelvic floor muscle (PFM) function but remains subjective and inconsistently taught. We evaluated the accuracy and reliability of SimLevator®, a simulator that reproduces graded contraction strength and resting tone.

Methods

Three expert pelvic health physiotherapists (≥10 years’ experience) independently rated simulated strength using the Modified Oxford Scale (MOS; 0-5) and tone using a three-level ordinal scale (decreased/normal/increased). Following standardised training with feedback, each rater completed two blinded, randomised assessment rounds without feedback, comprising 60 strength and 30 tone trials per round. Outcomes included device-rater agreement, inter-rater and intra-rater reliability (quadratic-weighted Cohen’s κ and Light’s κ), and exact agreement.

Results

For strength, device-rater weighted κ values were 0.997-0.999, with 98.3-99.2% exact agreement. For tone, weighted κ values were 0.974-1.000, with 96.7-100% exact agreement. Inter-rater reliability was 0.995 (95% CI 0.991-0.999) for strength and 0.983 (95% CI 0.954-1.000) for tone. Intra-rater reliability was 0.994-0.997 for strength and 1.000 for tone; all p

Zitieren

APA

Orth, D., Heath, M., Berry, L., Igualada-Martinez, P., & Spinelli, G. (2026). Expert practitioner accuracy and reliability when assessing a novel dynamic pelvic floor muscle simulator for tone and strength. Continence, 102922. https://doi.org/10.1016/j.cont.2026.102922

Vancouver

Orth D, Heath M, Berry L, Igualada-Martinez P, Spinelli G. Expert practitioner accuracy and reliability when assessing a novel dynamic pelvic floor muscle simulator for tone and strength. Continence. 2026:102922. doi:10.1016/j.cont.2026.102922

BibTeX
@article{Orth2026,
  author = {Orth, Dominic and Heath, Maia and Berry, Lucia and Igualada-Martinez, Paula and Spinelli, Gabriella},
  title = {Expert practitioner accuracy and reliability when assessing a novel dynamic pelvic floor muscle simulator for tone and strength},
  journal = {Continence},
  year = {2026},
  pages = {102922},
  doi = {10.1016/j.cont.2026.102922}
}
Kostenlos starten →