EUVIMEDEUVIMED entdecken
Crossref

OSAM-NET: A multi-feature fusion model for measuring fetal head flexion during labor with transformer multi-head self-attention

Shijie Zhang, Shaozheng He, Jingjing Wu, Dandan Wang, Pan Zeng, Guorong Lyu

Computerized Medical Imaging and Graphics · 2025

DOI: 10.1016/j.compmedimag.2025.102582 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computerized Medical Imaging and Graphics, 2025. Verfasst von Shijie Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Artificial Intelligence Professional Group, Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian Provi…. Hauptthemen laut MEDLINE: Ultrasonography, Prenatal, Head, Neural Networks, Computer, Labor Presentation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: Second Affiliated Hospital of Fujian Medical University, Fujian Provincial Department of Science and Technology, Fujian Medical University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fetal head flexion is essential during labor. The current assessment presents technical challenges for unskilled ultrasound operators. Therefore, the study aimed to propose an occiput-spine angle measurement network (OSAM-NET) to improve the accuracy and intrapartum applicability of fetal head flexion assessment. We used YOLOv8 to extract key anatomical structures (occiput and spine) and Vision Transformer to extract global features on ultrasound images of the posterior mid-sagittal section of the fetus (PMSF). Then, by fusing the geometric location information and global features through the multi-head self-attention mechanism, we constructed the multi-feature fusion model OSAM-NET. The model was able to extract intricate features from multi-dimensional information, effectively boosting the accuracy of occiput-spine angle (OSA) prediction. We curated the first OSA dataset comprising 1688 high-quality, clear PMSF ultrasound images and annotations to train and test our model. We evaluated the performance of OSAM-NET and compared it with other models. The results showed that OSAM-NET outperformed the comparison models on all evaluation metrics, with R² increasing by nearly 13 %, and root mean square error (RMSE) and mean absolute error (MAE) decreasing by approximately 15 % and 20 %, respectively. The intraclass correlation coefficient (ICC) improved by about 8 %, with the average value reaching 0.89, indicating good agreement with the measurements of ultrasound experts. The multi-feature fusion model OSAM-NET demonstrates strong applicability and predictive accuracy for complex ultrasound images. This study provides a reliable and efficient tool for automatically evaluating fetal head flexion. The real-world application potential has been validated on prospective test dataset.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ultrasonography, PrenatalHeadNeural Networks, ComputerLabor PresentationHumansPregnancyFemale

Stichwörter der Autor:innen

Automatic measurementIntrapartum ultrasoundMulti-head self-attentionOcciput-spine angleVision Transformer

Autor:innen und Institutionen

  • Department of Ultrasound, Artificial Intelligence Professional Group, Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian Province, China.
  • Department of Obstetrics and Gynecology, Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian Province, China.
  • Research and Development Department of Xingfan Technology, Sichuan, Chengdu Province, China. Electronic address: 954181775@qq.com.
  • Department of Ultrasound, Artificial Intelligence Professional Group, Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian Province, China; Department of Clinical Medicine, Quanzhou Medical College,…

Förderung

  • Second Affiliated Hospital of Fujian Medical University
  • Fujian Provincial Department of Science and Technology
  • Fujian Medical University

Zitieren

APA

Zhang, S., He, S., Wu, J., Wang, D., Zeng, P., & Lyu, G. (2025). OSAM-NET: A multi-feature fusion model for measuring fetal head flexion during labor with transformer multi-head self-attention. Computerized Medical Imaging and Graphics. https://doi.org/10.1016/j.compmedimag.2025.102582

Vancouver

Zhang S, He S, Wu J, Wang D, Zeng P, Lyu G. OSAM-NET: A multi-feature fusion model for measuring fetal head flexion during labor with transformer multi-head self-attention. Computerized Medical Imaging and Graphics. 2025. doi:10.1016/j.compmedimag.2025.102582

BibTeX
@article{Zhang2025,
  author = {Zhang, Shijie and He, Shaozheng and Wu, Jingjing and Wang, Dandan and Zeng, Pan and Lyu, Guorong},
  title = {OSAM-NET: A multi-feature fusion model for measuring fetal head flexion during labor with transformer multi-head self-attention},
  journal = {Computerized Medical Imaging and Graphics},
  year = {2025},
  doi = {10.1016/j.compmedimag.2025.102582}
}
Kostenlos starten →